Permit Number: T07CM00716
Parcel: 11522002A

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T07CM00716
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/20/2007 CRAIG GROSS ZONING REVIEW Denied need meeting with architect to resolve zoning problems
11/20/2007 WILLDAN ADA REVIEW Approved
11/20/2007 CRAIG GROSS ZONING REVIEW Denied please provide the following corrections:

1. existing sidewalks on Speedway.

2. pedestrian access from ROW to building.

3. truncated domes in ROW

4. extend sidewalk in front of parking immediately to north to provide approriate pedestrian access.

5. provide depressed area for ADA parking access.

6. provide appropriate ADA signage for ADA parking spaces

7. sidewalk is to physically separated from driveway by curbing, grade separation, barriers, etc. Sidewalk adjacent to driveway cannot be at same grade of paving.

8. provide ROW information on Speedway (existing and future)

9. who is providing landscape plan for area between building and sidewalk?
11/20/2007 WILDAN 2ND PARTY REVIEW REVIEW Approved
11/23/2007 PATRICIA GILBERT ENGINEERING REVIEW Denied DATE: November 23, 2007
ACTIVITY NUMBER: T07CM00716
PROJECT NAME: First Tee Clubhouse El Rio Golf Course
PROJECT ADDRESS: 1400 West Speedway Blvd.
PROJECT REVIEWER: Patricia Gilbert, Engineering Associate

The following items must be revised or added to the site plan. Please include a response letter with the next submittal that states how all comments have been addressed.


RESUBMITTAL REQUIRED: SITE PLAN

1. Provide future sight visibility triangles for the ingress/egress to Speedway Blvd. DS 2-02.2.1.A.10., DS 3-01.5.0.

2. Provide cut and fill quantities in cubic yards on the site plan. If the cut and fill quantities equal zero indicate on the plan. DS 2-02.2.1.A.17.

3. Provide from the street centerline of Speedway Blvd. the future and existing ½ ROW width, curb and sidewalk location. If the existing ROW width is the same as the future ROW width clear indicate on the plan. DS 2-02.2.1.A.19., 21.

4. Clearly indicate on the plan the connection the sidewalk from the proposed structure to the ADA ramp located within the ROW. Be advised the ramp may need to be revised to meet current code.
11/30/2007 GERRY KOZIOL WWM REVIEW Denied NEEDS TO SHOW METHOD/CONNECTION TO PUBLIC SEWER.
NEEDS 8TH FLOOR CREDIT EVALUATION
12/06/2007 ROBERT SHERRY WATER REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
12/28/2007 SUE REEVES OUT TO CUSTOMER Completed
12/28/2007 SUE REEVES REJECT SHELF Completed