Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T07CM00660
Review Name: RESUBMITTAL
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
05/25/2007 | SREEVES1 | 2ND PARTY REVIEW | REVIEW | Denied | May 25, 2007 CITY OF TUCSON – THIRD CHECK Tucson Appl. No. T06CM00660 Bureau Veritas Job No. 01007-161001.018 Mr. Todd Rutledge U.S. Builders 2425 E. Camelback Rd. Ste # 950 Phoenix, Arizona 85016 Re: Plan Review: U.S. Builders-Lot 17 Starr Pass Address: 2065 S. Twinkling Starr Dr Dear Mr. Rutledge, Bureau Veritas North America has completed a third review of the following documents on behalf of the City of Tucson: Plans: Two (2) sets of building plans (19 sheets, G1.1 through E1.1) dated February 9, 2007 by Soumya Biswas for Consulting Engineers Corporation. Structural Calculations: Two sets of calculations dated February 9, 2007, by Soumya Biswas for Consulting Engineers Corporation. Truss Calculations: None submitted with this review. These documents were reviewed only for their conformance to the provisions of the 2003 International Building Codes (i.e., State of Arizona and Tucson amended 2003 IRC, 2003 IMC, 2002 NEC and 2003 IPC). Please submit an itemized response letter and required number of complete and revised documents with all revisions clouded. Sincerely, Bureau Veritas North America Randy McCoy ICC Plans Examiner RMC;rmc Re: Stories: One Occupancy: R-3/VB Building Area (sq. ft.): 3391 (livable) 973 (porch) 920 (garage) 5284 Total sq. ft. A. The following plan review comments are based on the City of Tucson Building Regulations and referred to the 2003 International Building Code. B. Please respond in writing to each comment by marking the attached comment list or creating a response letter. Indicate which detail, specification, or calculation shows the requested information. Your complete and clear responses will expedite the re-check and hopefully, approval of this project. Thank you for your assistance. C. These plan review comments are based on building code items only. If site-related comments are applicable to this project, they will be generated by others (e.g., County Engineering, Public Works, Health, etc.). PLUMBING COMMENTS: Provide a legible plumbing floor plan showing all plumbing fixtures, supply, waste, and gas lines. Indicate sizes of all plumbing lines, vents, cleanouts, etc. Provide isometric diagrams as needed to clearly convey the design. These drawings must be incorporated onto the plans. No small-sized sheets attached to the drawings will be allowed. Provide a detail for island sink venting. Provide a gas isometric with length of line(horizontal and vertical) to each appliance, BTU demand of each appliances, size of each branch, total demand and size of the meter. Provide a drainage pipe isometric showing all drain, waste and vent piping. Note that drainage piping serving fixtures which have flood level rims located below the elevation of the next upstream manhole cover of the public sewer shall be protected from backflow of sewage by a backwater valve. IRC Sec P3008. Specify materials for gas pipes. If you have any questions regarding the above comments, please contact Randy McCoy at (520) 820-1980 between 8:00 A.M. to 5:00 P.M., M-F. |
05/31/2007 | MATT FLICK | ENGINEERING | REVIEW | Needs Review | |
05/31/2007 | VFLORES1 | ZONING | REVIEW | Needs Review |