Permit Number: T07CM00644
Parcel: 107150140

Address:
614 E GLENN ST

Review Status: Active

Review Details: SITE

Permit Number - T07CM00644
Review Name: SITE
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
03/27/2007 STEVE SHIELDS ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: Stuttgart Autohaus
T07CM00644
Site Plan (1st Review)

TRANSMITTAL DATE: April 2, 2007

COMMENTS: Please resubmit revised drawings and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. This site plan was reviewed for compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC) for full code compliance for the expansion area only.

2. Based on the last approved site plan there is a large portion of the R2 parcels which was not designated as vehicle parking or storage. This said per the current aerial photos this area is being used as vehicle parking or storage. This use is not allowed in an R2 zone.

3. This site is comprised of four (4) parcels, show all parcels on the plan.

4. D.S. 2-02.2.1.4 Provide a location map which meets the minimum requirements of D.S. 2-05.2.1.D in the upper right hand corner of the plan. Show the subject property approximately centered in the one (1) square mile area, identify conditions within the square mile area, such as major streets and watercourses, section, township and range, north arrow and scale.

5. D.S. 2-02.2.1.4 Provide lot line bearings on the plan.

6. D.S. 2-02.2.1.7 the existing structures that are shown as to be removed, loose their non-conforming status once they have been demolished. The new proposed structures are required to meet setbacks based on LUC Sec. 3.2.6.4 Perimeter Yard Indicator "DD". This setback to the R2 zoned parcel to the south is one and one-half (1-1/2) the proposed building wall height. Provide a dimension that shows that this setback is met.

7. D.S. 2-02.2.1.7 Provide a setback dimension from the east end of the proposed structure to the east property line.

8. D.S. 2-02.2.1.8 Based on the current aerial photos of this site the existing parking does not match the last approved site plan. Provide the current parking on the plan so that zoning can verify that the minimum requirements of the last approved site plan are met.

9. D.S. 2-02.2.2.A.1 Provide the gross lot area on the plan.

10. D.S. 2-02.2.2.A.3 Provide the allowed and provided floor area ratio (FAR) on the plan.

11. D.S. 2-02.2.2.A.4 Provide required and provided vehicle and bicycle parking space calculation on the plan.

12. Additional comments may be forth coming depending on how each comment has been addressed.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 873-4956

C\planning\cdrc\finaplat\t07cm00644.doc.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents.
04/02/2007 ANDREW CONNOR NPPO REVIEW Passed
04/02/2007 ANDREW CONNOR LANDSCAPE REVIEW Passed
04/02/2007 STEVE SHIELDS ZONING HC SITE REVIEW Passed
04/16/2007 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
04/17/2007 SHANAE POWELL REJECT SHELF RECEIVED