Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T07CM00524
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/05/2007 | STEVE SHIELDS | ZONING | REVIEW | Denied | DSD TRANSMITTAL FROM: Steve Shields Lead Planner PROJECT: Bond Tucson Residence 3180 W. Mockingbird Lane T07CM00524 Site Plan (1st Review) TRANSMITTAL DATE: March 5, 2007 COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. This site plan was reviewed for compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC). 2. Add a note to the plan stating "THIS SITE PLAN IS DESIGNED TO MEET THE REQUIREMENTS OF THE OVERLAY ZONES CRITERIA: SEC. 2.8.1, HILLSIDE DEVELOPMENT ZONE (HDZ) AND SEC. 2.8.6M ENVIRONMENTAL RESOURCE ZONE (ERZ). 3. Zoning is not able to verify the building height. Provide building elevations with your next submittal. Per LUC Sec. 2.8.1.8.A the maximum building height is twenty-four (24) feet. 4. Provide a note on the plan that states "ALL PROPOSED SITE WORK, INCLUDING GRADING, WILL COMPLY WITH DEVELOPMENT STANDARD 9-01.0". 5. Provide a note on the plan that states "ALL EXPOSED EXTERIOR WALLS AND ROOFS OF STRUCTURES, RETAINING WALLS, AND ACCESSORY STRUCTURES, EXCEPT SATELLITE DISHES, SHALL BE EARTH TONE IN COLOR AND WILL BLEND WITH THE PREDOMINANT NATURAL COLORS FOUND ON THE PARCEL. SATELLITE DISHES MAY BE BLACK". 6. Provide a note on the plan that states "THIS PROJECT IS DESIGNED TO COMPLY WITH CITY OF TUCSON HDZ GRADING, CUT AND FILL, VEGETATION, RETENTION AND SLOPE STABILIZATION REQUIREMENTS PER DEVELOPMENT STANDARDS 9-04.3.1 AND DEVELOPMENT STANDARDS 9-04.3.2 & LAND USE CODE SECTION 2.8.1. ALL AREAS AFFECTED BY GRADING IN ALLOWABLE AREAS WILL BE REFEGETATED IN ACCORDANCE WITH C.O.T. STANDARDS". 7. This site plan cannot be approved until the grading plan (T07BU00332) is approved by all Development Services agencies. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 791-5608 ext. 1180. C:\planning\site\t07cm00524.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site/grading plan and additional requested documents |
| 03/12/2007 | ANDREW CONNOR | NPPO | REVIEW | Denied | To protect the natural areas, a covenant must be provided with record interest in the natural area in favor of the City of Tucson per LUC 2.8.1.7.D. Submit the required covenant and legal description for review. The natural area percentage must also be delineated in a surveyable manner and designated by legal description on a document recorded with the Pima County Recorder. |
| 03/22/2007 | ELIZABETH EBERBACH | ENGINEERING | REVIEW | Approv-Cond | DATE: March 22, 2007 SUBJECT: 3180 W Mockingbird Lane (T06SA00107) Engineering Resubmittal Review REVIEWER: Elizabeth Eberbach ACTIVITY NUMBER: T07BU00332, T07CM0524 SUMMARY: The residential grading plan, overlay site plan, and associated HDZ Overlay documents were reviewed by Engineering with Stantec and owner at a meeting on 22MAR07. Engineering recommends conditional approval of the grading plan upon Overlay approval. One copy of the HDZ documents, including documentation of approval for the overlay will be needed for grading permit approval. Submit 4 copies of the grading plan with supporting documents. For questions or to set up a meeting, call me at 791-5550, extension 2204. Elizabeth Eberbach, PE Civil Engineer Engineering Division Development Services |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/22/2007 | FSANCHE1 | OUT TO CUSTOMER | Completed |