Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T07CM00439
Review Name: COMMERCIAL TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/06/2007 | MICHAEL ST. PAUL | ZONING | REVIEW | Approved | |
| 02/06/2007 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | 1. Show the size of the combustion air duct for the mechanical room. Is this a one-opening system? |
| 02/06/2007 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Denied | T07CM00439 2/6/07 1. Please identify an electrical panel and circuit for the Exhaust Fan indicated on Sheet M-1. |
| 02/06/2007 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 02/06/2007 | LEERAY HANLY | BUILDING-COMMERCIAL | REVIEW | Approved | |
| 02/06/2007 | PATRICIA GILBERT | ENGINEERING | REVIEW | Approved | |
| 02/06/2007 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Where is the water heater? 2. Show the gas piping to the furnace and the water heater. 3. Show the automatic shut off valve for the equipment under the hood. 4. Show the applicable standards for the owner-furnished fixtures. 5. Justify indirectly wasting the new bar sink (keynote 9). 6. If the ice machine does not have an approved air gap or integral backflow protection assembly, provide an approved backflow protection device. |
| 02/06/2007 | DAVE MANN | FIRE | REVIEW | Approved | |
| 02/13/2007 | DROBEY1 | WWM | REVIEW | Needs Review | |
| 02/13/2007 | BETH GRANT | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Completed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/13/2007 | DELMA ROBEY | APPROVAL SHELF | Completed |
| 02/13/2007 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 02/13/2007 | DELMA ROBEY | REJECT SHELF | Completed |