Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - SITE ALL
Permit Number - T07CM00407
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/03/2007 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 08/07/2007 | STEVE SHIELDS | ZONING HC SITE | REVIEW | Approved | |
| 08/07/2007 | STEVE SHIELDS | ZONING | REVIEW | Denied | DSD TRANSMITTAL FROM: Steve Shields Lead Planner PROJECT: Bryant Avenue Warehouse T07CM00407 Site Plan (2nd Review) TRANSMITTAL DATE: August 7, 2007 COMMENTS: Please resubmit revised drawings and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. This site plan was reviewed for compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC) for full code compliance. 2. The certificate of occupancy for this project will not be issued until violation T07DV06636 has been cleared. 3. Per D.S. 2-09.4.3 Bicycle parking facilities will be separated from vehicular parking and drive areas by a barrier of sufficient distance to prevent damage to the parked bicycles. This said provide some type of barrier that will protect the bicycles. 4. The provided bicycle detail shows 1'-6" provided from the end of the rack to the railing and 2'-0" from the side of the rack to the railing. Per D.S. 2-09.5.1.B the required distance from the end of the rack is 36", and from the side of the rack is 30 ". 5. Provide a dimension from the proposed railings at the handicapped access ramp to the west side of the PAAL. D.S. 2-02.2.1.A.11. 6. Remove all revision clouds from the plan. Revision clouds are not necessary until after the plan are approved. 7. Ensure that all changes to the site plan are reflected on the landscape plan. 8. Once all comments above have been addressed zoning will provide an over the counter review. Call or email for an appointment. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956 C:\planning\site\t07cm00407-3rd.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents |
| 08/08/2007 | PATRICIA GILBERT | ENGINEERING | REVIEW | Denied | DATE: August 8, 2007 ACTIVITY NUMBER: T07CM00407 PROJECT NAME: Bryant Avenue Warehouse PROJECT ADDRESS: 1124 North Bryant Avenue PROJECT REVIEWER: Patricia Gilbert, Engineering Associate The following items must be revised or added to the site plan. Please include a response letter with the next submittal that states how all comments have been addressed. RESUBMITTAL REQUIRED: SITE PLAN 1. Revise the site plan to remove the railing that blocks pedestrian access to the building. |
| 08/10/2007 | DROBEY1 | PLUMBING-COMMERCIAL | REVIEW | Needs Review | |
| 08/10/2007 | DROBEY1 | LANDSCAPE | REVIEW | Needs Review | |
| 08/10/2007 | DROBEY1 | NPPO | REVIEW | Needs Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/10/2007 | DELMA ROBEY | APPROVAL SHELF | Completed |
| 08/10/2007 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 08/10/2007 | DELMA ROBEY | REJECT SHELF | Completed |