Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T07CM00241
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/23/2007 | WILDAN | 2ND PARTY REVIEW | REVIEW | Denied | May 23, 2007 City of Tucson Development Services P.O. Box 27210 Tucson, AZ 85726 RE: Maldonado Garage/Patio Addition – 3rd REVIEW CITY OF TUCSON LOG NO. T07CM00241 WILLDAN PROJECT NO. 13881-7014 The third review for the above project has been completed. This letter contains comments which need to be addressed by written responses to each which indicate any actions taken. In order to facilitate a shorter second review, all corrections and revisions must be made on the original plans and two complete new sets of prints, along with one complete redlined set, must be returned to our office. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets, and that all changes have been highlighted with appropriate revision numbers, revision dates, and “cloud bubbles.” Pen or pencil corrections on final prints are not acceptable. This project has been reviewed for conformance with the 2003 IRC, 1997 UAC, and the 2003 UPC. Any revisions to this plan will require an additional review and approval by Willdan. Should you have questions regarding the comments herein, please contact your plans examiner Chris Kiel. Occupancy Occup. Load Construction Area S.F. Sprinklered Alarms Garage Porch N/A V-B 2094 2080 No None Special Inspection is required for the following items: N/A The following items are acceptable for deferred submittals: Trusses GENERAL COMMENTS: General A deferred submittal letter for trusses will need to be forwarded directly to the Building Official and approved and a copy of the approved to Willdan prior to the plans being delivered to the City. Reference the City of Tucson Submittal Policy. Comment remains. Please submit a deferred submittal letter to the Building Official of the City of Tucson to sign and date the letter. ARCHITECTURAL COMMENTS: Reviewed and accepted. STRUCTURAL COMMENTS: Reviewed and accepted. ELECTRICAL COMMENTS: Sheet 3 Please provide cut sheets for all the exterior light fixtures shown or noted. The cut sheets need to provide lumens per fixture and show if the fixture is a full cut-off, which means no light is emitted at or above the horizontal plane. Please provide cut sheets and calculations for all exterior lighting fixtures. Reference the City of Tucson Outdoor Lighting Code. Comment remains. Please include all fixtures, including exisiting. Please specify how many lamps of each type are being used for the exterior lighting. Lumens will be calculated by the maximum allowed watts for each fixture that the manufacturer specifies. Reference the City of Tucson Outdoor Lighting Code. Comment remains. Please include all fixtures, including exisiting. Cross-reference exterior lighting fixtures on the plans with the cut sheets and calculations submitted. Reference the City of Tucson Submittal Requirements. Comment remains. Please include all fixtures, including exisiting. ENERGY CODE COMMENTS: Reviewed and accepted. ACCESSIBILITY COMMENTS: Reviewed and accepted. Sincerely, WILLDAN Chris Kiel, C.B.O., M.C.P. Building Official CEK/jk |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 05/29/2007 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
| 05/29/2007 | SUE REEVES | REJECT SHELF | Completed |