Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T07CM00113
Parcel: 125050220

Address:
825 N NORTON AV

Review Status: Completed

Review Details: RESIDENTIAL BLDG/WWM

Permit Number - T07CM00113
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/11/2007 GERRY KOZIOL WWM REVIEW Denied property does not front public sewer. Needs 8th floor review
05/24/2007 CLAYTON TREVILLYAN BUILDING-RESIDENTIAL REVIEW Denied PLAN REVIEW COMMENTS
Activity # T07CM00113
Date: 5/25/07

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken.

SCOPE OF REVIEW:
The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2003 International Residential Code, 2003 International Energy Conservation Code, and Arizona State amendments to the 2003 Uniform Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

GENERAL REQUIREMENTS:
All corrections and revisions shall be made on original tracings or finished reproducible set. Return this set and a copy along with a set of the first submission. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets.

· Provide a note for underground facility tracer wires per DSD Memo, 10/24/2005.

I. FOUNDATION:
1. Note on the drawings the allowable soil bearing pressure used in the design of the footings, or state that the assumed value of 1500 PSF is being used per Table R401.4.1 if a soils report is not provided.
2. Anchor bolts require minimum 7" embedment into concrete or masonry, R403.1.6 (8" bolts will not be long enough).
3. Specify maximum allowable stem wall height for submitted design.

II. FLOOR PLAN:
1. Note the minimum required area for shower compartments, P2708.1
2. Provide location and specifications for handrails serving stairways of four or more risers, R311.5.6.

III. STRUCTURAL PLAN:
1. Specify design criteria on plans. Provide values for floor dead load and live load as well as roof dead load and live load, R301.1.
2. Note and detail double joists parallel to headers at framed openings and framing anchors for header supports, R802.9.
3. Justify header sizes for (2) 2x10 at studio, (2) 2x10 at hall, and (2) 2x8 at breezeway.
4. Specify the number of required jack studs under headers (when number exceeds 1 each side), Table R502.5(1).
5. Provide location of all braced wall panels or comply with continuous sheathing requirements, R602.10.5
6. Specify type of joist hangers used.

IV. SECTIONS - DETAILS:
1. Justify rafter size and spacing for 6' cantilever
2. Justify rafter size and spacing for point load under solar collector.
5. Show the ceiling gypsum board as either 5/8" or ½" sag resistant when applied to 24" o/c framing, Table R702.3.5 footnote d.
3. Provide flashing detail for metal siding over cantilevered breezeway roof (refer to M/A6.4).

V. PLUMBING PLAN:
1. Clarify size of new gas line (plumbing plan note calls for 1½").
2. Provide gas line isometric for clarification.
3. Provide expansion tank for solar-powered water heater collector or note on plan specifications of installation.
4. Clarify size of water pipe prior to fixture P1 (isometric and plumbing plan disagree).
5. Provide vent piping through the roof so that the aggregate cross-sectional area shall not be less than that of the largest required building sewer, UPC 904.1.

VI. MECHANICAL PLAN:
1. Gas appliances shall comply with ARIZONA STATE PLUMBING CODE combustion air requirements or Chapter 17, 2003 IRC. Show compliance for all appliances. Confined spaces require a minimum of two 100 SQ. IN. openings, M1702.2.
2. Provide location and termination of condensate drains, M1411.3.

VII. ELECTRICAL PLAN:
1. Specify circuit number serving hallway receptacles.

VIII. OUTDOOR LIGHTING CODE:
1. Full cut-off fixtures have no emittance above the nadir (fixtures are completely opaque above and to the lowest point of the lamp). Fixtures may be exempt from the total lumen budget if both of the full cut-off FCO style and located under overhangs, OLC 5.1.2.
· Flood lamp on the West studio wall does not qualify for FCO status.
· The two lamps on the North studio wall are not under an overhang.
2. Include all exterior fixtures on the property in the outdoor lighting calculations (include existing), the total property lighting limit for area E3 is 55,000 lumens per acre and the unshielded limit for area E3 is 12,000 lumens per acre, OLC 3.1.2.

If you have any questions please contact:
Clayton Trevillyan
(520) 837-4913
City of Tucson Residential Plan Review

Final Status

Task End Date Reviewer's Name Type of Review Description
05/29/2007 CINDY AGUILAR OUT TO CUSTOMER Completed
05/29/2007 CINDY AGUILAR REJECT SHELF Completed