Permit Review Detail
Review Status: Active
Review Details: GRADING
Permit Number - T07BU02552
Review Name: GRADING
Review Status: Active
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/10/2008 | ANDREW CONNOR | NPPO | REVIEW | Approved | |
| 03/25/2008 | MICHAEL ST. PAUL | ZONING | REVIEW | Denied | March 26, 2008 Development Services Department Zoning Review Section Michael St.Paul Planning Technician T07BU02552 Grading Plans for D06-0038 6279 East Hawthorne Street Comments: 1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed. 2. Please provide the required maximum slope in percentages for the accessible routes and the parking area on the grading plan. 3. Zoning will re-review the grading plan on the next submittal to ensure compliance with the approved development plan. Additional comments may be forthcoming. |
| 03/28/2008 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Denied | DATE: March 31, 2008 SUBJECT: Grading Plan TO: Mead Meyer Construction LOCATION: 6279 E , T13S, R14E, Section 36, Ward 28 REVIEWERS: Bianca Ramirez, CFM ACTIVITY: T07BU02282 (Third Review) RESUBMITTAL REQUIRED: Grading Plan SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed grading plan for the above referenced property. Engineering Division does not recommend approval of the grading plan at this time. Please address the following review comments prior to the next submittal. Provide a response letter to the comments along with the corrected copies of the site plan. Grading Plan: 1. Complied 2. Complied 3. Complied 4. Be advised that detail 207 has been revised. Ensure that most recent detail is being utilized and indicated detail on grading plan. 5. Complied 6. See general note (2) and provide spaces on plan as noted. 7. Complied 8. Complied 9. Provide section corners on within location map and label appropriately. 10. Provide north arrow for the grading plan drawing. 11. Provide legend and show all symbols in the legend. 12. List all Cut and Fill quantities in cubic yards on grading plan. Provide cut and fill quantities in table format for easy reference. 13. Provide curb to separated parking area and adjacent areas. 14. Call out surface paving material and provide details of all surface materials - specifically for paving. 15. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information. 16. Complied 17. Indicate flow rates within and adjacent to site to show drainage scheme. 18. Complied 19. Identify water harvesting areas on grading plan and provide depressed curbing to permit water to enter into proposed water harvesting areas. Specifically call out water harvesting area located along eastern side of proposed parking area. 20. List development number, grading plan and zoning condition, etc. 21. Show cross section with transverse and longitudinal slopes. 22. Please show the proposed rood drainage patterns, 100% of the 10-year flow must be conveyed under the sidewalks. Please provide supporting calculations to demonstrate compliance with D.S. 3-01.4.4. If the location(s) of the roof scuppers have not yet been decided, add a general note indicating sidewalk scuppers (per COT/SD) will be used when the roof scuppers location have been designed. 23. Provide radius for back up spur and dimension back up distance. 24. Call out peak discharges entering and exiting the site. 25. Additional comments may be forthcoming. If you have any questions, I can be reached at 791-5550 x1193 or BiancaRamirez@tucsonaz.gov Bianca Ramirez Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4928 office (520) 879-8010 fax |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/31/2008 | SUE REEVES | REJECT SHELF | RECEIVED |