Permit Number: T07BU02444
Parcel: 122184340

Review Status: Completed

Review Details: RESUBMITTAL - GRADING ALL

Permit Number - T07BU02444
Review Name: RESUBMITTAL - GRADING ALL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/18/2008 ANDREW CONNOR NPPO REVIEW Approved
03/26/2008 HEATHER THRALL ZONING REVIEW Denied Zoning will continue the review of the grading plan once Engineering has approved it. When you make your counter appointment with me to address the minor remaining comments for the site plan, let's review the grading plan as well.

Email me at Heather.Thrall@tucsonaz.gov to set up a time.
04/29/2008 PAUL MACHADO ENGINEERING REVIEW Denied To: Louis Catallini DATE: April 28, 2008
Baker and Associates Engineering, Inc.
3561 E. Sunrise Drive, Ste. 225
Tucson, Arizona 85718

SUBJECT: Monte V Corp. Ctr., 3501 E. Speedway Blvd.
Grading plan T07BU02444 (Second Review)
T14S, R14E, Section 04

RESUBMITTAL REQUIRED: Grading Plan

The Grading Plan (GP) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Grading Plan:
1. Please include a response letter to the comments along with the corrected copies of the GP.
2. All recording information shown on the grading plan for the abandonment of the eamts.shall be completed prior the approval of the GP.
3. Add note: "Depress all landscaped areas a maximum of 6" for water harvesting". Show depressed curbs at planters for water harvesting. Per previous comment.
4. Show details, with dimensions, of all retention/detention basins in the GP.
5. Add the following notes to the grading plan notes: Per previous comment.
" "The approved Grading Plan is the only acceptable construction plan onsite. The Contractor may not use any other plans, such as the approved Tentative Plat and/or Development Plan, for construction purposes. The Contractor may ask the Development Services Inspector to consult with the other approved plans for additional information or details that might not be included on the approved grading plan but needed for completion of work."

" "The contractor shall remove the fine materials from the bottom of the detention/retention basin and scarify the basin bottom once the construction activities are completed in order to remove any fine material build up caused by construction and to restore soil percolation."

" "Any engineering work to be done below grade (i.e. toe-downs, cutoff walls, drainage pipes/structures, etc.) shall not be back filled until Development Services Inspector inspects the work and approves it."

6. Dimension from street monument lines to existing and proposed curbs, sidewalks, driveways, and utility lines per D.S. 2-02.2.1.21. Per previous comment.
7. Show refuse container location, size, and access thereto fully dimensioned per D.S. 2-02.2.1.32 and D.S. 6-01.0. Provide an adequate number of dimensions in order to build and inspect the refuse enclosure. Per previous comment.
8. Cut or fill slopes require a 2' minimum setback from property line. Per previous comment.
9. Call out peak discharges entering and exiting the site. Per previous comment.

Drainage Report:
1. Please include a response letter to the comments along with the corrected copies of the DR.
2. Add the basin(s) maintenance responsibility note verbatim per S.M.D.D.F.M. 2.3.1.6 C 1 and 2 to the DR.
3. Show details, with dimensions, of all retention/detention basins in the DR.
4. An orifice plate shall be used at the upstream end of each pipe. The orifice shall have a lesser opening than that of the size of the pipe.

Stormwater pollution prevention plan:
1. The SWPPP has been accepted be engineering.
2. Include the two copies of the SWPPP with the revised Grading Plan (3 sets) and the revised Site Plan (2 sets) in the next submittal.




If you have any questions, I can be reached at 837-4932 or Paul.Machado@tucsonaz.gov
Paul P. Machado
Senior Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 837-4932 office
(520) 879-8010 fax
C:\ 3501 E. Speedway Blvd. Grad

Final Status

Task End Date Reviewer's Name Type of Review Description
05/01/2008 DELMA ROBEY OUT TO CUSTOMER Completed
05/01/2008 SHANAE POWELL REJECT SHELF Completed