Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - GRADING
Permit Number - T07BU02441
Review Name: RESUBMITTAL - GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/24/2008 | MICHAEL ST. PAUL | ZONING | REVIEW | Denied | January 24, 2008 Development Services Department Zoning Review Section Michael St.Paul Planning Technician T07BU02441 Grading Plans for T07CM03055 155 South Panorama Circle Comments: 1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed. 2. In addition, we could not verify that the grading plan was in compliance with a site plan for this site approved by Zoning Review. Please submit two copies of the approved and stamped Site Plan, Landscape, and NPPO plans with the next grading plan submittal. 3. Zoning will re-review the grading plan on the next submittal to ensure compliance with the approved development plan. Additional comments may be forthcoming. |
| 01/24/2008 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Denied | DATE: January 24, 2008 SUBJECT: Residence and Studio for: William and Maria Elena Maytorena TO: Manny Delgado LOCATION: 155 S Panorama Circle, T14S R13E Sec15, Ward 1 REVIEWERS: Bianca Ramirez, CFM ACTIVITY: T07CM03055 (Third Review) RESUBMITTAL REQUIRED: Site/Grading Plan SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed site plan for the above referenced property. Engineering Division does not recommend approval of the site plan at this time. The following items need to be addressed to the next submittal: Site Plan: 1. Please include a response letter to the comments along with the corrected copies of the Site Plan. 2. Complied. 3. Complied 4. D.S. Sec.2-02.2.1.11: Label material that is proposed for driveway. Slope of driveway exceeds maximum 15% slope per ADA. 5. Complied 6. Complied 7. Complied 8. Complied 9. Complied 10. D.S. 2-02.2.1.29: Show Grading Plan number T07BU02441 on All sheets. 11. Complied 12. See additional comments #25- #29 13. Complied 14. Complied 15. Complied 16. Complied 17. Complied 18. Complied 19. Grading information, including proposed contours and locations of all areas of cut and fill. 20. Complied 21. Complied 22. Differential grading may be applicable verify that grading is not more that 2' from existing to proposed. 23. If you would like to meet with me to review the comments please call to set up an appointment. 24. Complied 25. Provide finished floor elevation for residence and garage. 26. Grade gutter appears to concentrate flow and discharge onto adjacent property. Provide adequate area for spillway and erosion protection. In addition, provide side yard swales along northern and southern portion of parcel. 27. Provide cross sections as depicted on plans. Northern cross-section should go through the patio through property line including side yard with erosion protection. Southern cross-section should go through the sidewall through property line including side yard with erosion protection. 28. Provide bottom finished floor of balcony on plan. 29. Label type of curbing for 1' type curb. If you have any questions, I can be reached at 520-837-4928 or Bianca.Ramirez@tucsonaz.gov Bianca C. Ramirez Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4928 office (520) 879-8010 fax |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/28/2008 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
| 01/28/2008 | SHANAE POWELL | REJECT SHELF | Completed |