Permit Review Detail
Review Status: Completed
Review Details: GRADING
Permit Number - T07BU02441
Review Name: GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/30/2007 | MICHAEL ST. PAUL | ZONING | REVIEW | Denied | November 30, 2007 Development Services Department Zoning Review Section Michael St.Paul Planning Technician T07BU02441 Grading Plans for T07CM03055 155 South Panorama Circle Comments: 1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed. 2. In addition, we could not verify that the grading plan was in compliance with a site plan for this site approved by Zoning Review. Please submit two copies of the approved and stamped Site Plan, Landscape, and NPPO plans with the next grading plan submittal. 3. Zoning will re-review the grading plan on the next submittal to ensure compliance with the approved development plan. Additional comments may be forthcoming. |
| 12/04/2007 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Denied | DATE: December 5, 2007 SUBJECT: Residence and Studio for: William and Maria Elena Maytorena TO: Manny Delgado LOCATION: 155 S Panorama Circle, T14S R13E Sec15, Ward 1 REVIEWERS: Bianca Ramirez, CFM ACTIVITY: T07CM03055 (Second Review) RESUBMITTAL REQUIRED: Site/Grading Plan SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed site plan for the above referenced property. Engineering Division does not recommend approval of the site plan at this time. The following items need to be addressed to the next submittal: Site Plan: 1. Please include a response letter to the comments along with the corrected copies of the Site Plan. 2. Complied. 3. D.S. Sec.2-02.2.1.10: Label existing sight visibility triangles. Revise site visibility triangle that reads 180' to read 185'. 4. D.S. Sec.2-02.2.1.11: Label material that is proposed for driveway. 5. D.S. Sec.2-02.2.1.16: Provide additional drainage arrows throughout site and include percentage slopes. 6. Complied 7. Complied 8. Complied 9. Complied 10. D.S. 2-02.2.1.29: Show Grading Plan number T07BU02441 on all sheets. 11. Complied 12. D.S. Sec.11-01.8.2: Fill slopes shall not be constructed on natural slopes steeper than 1 unit vertical in 2 unit's horizontal (50% slope). The ground surface shall be prepared to receive fill by removing vegetation, non-complying fill, topsoil and other unsuitable materials scarifying to provide bond with the new fill and, where slopes are steeper than 1 unit vertical in 5 units horizontal (20% slope) and the height is greater than 5 feet (1524 mm), by benching into sound bedrock or other competent material as determined by the soils engineer. The bench under the toe of a fill shall be at least 10 feet (3048 mm) wide The area beyond the toe of fill is to be placed over a cut, the bench under the toe of fill shall be at least 10 feet (3048 mm) wide but the cut shall be made before placing the fill and acceptance by the soils engineer or engineering geologist or both as a suitable foundation of fill. Call out fill slopes on site. 13. Complied 14. D.S. Sec.11-01.9.2: 2' setback from property line is required. Or notarized letter from neighbor is needed permuting disturbance to occur within 2' of property line. 15. Complied 16. DS Sec.2-05.1.4.H.2: Review and approval from TDOT Permits and Codes for all proposed improvements including sidewalk within the public right of way will be required. A right-of-way use permit application will be required prior to construction. Contact Steve Tineo at 741-3115 for all right-of-way requirements and permit applications. 17. Complied 18. Complied 19. Grading information, including proposed contours and locations of all areas of cut and fill. 20. Complied 21. Complied 22. Differential grading may be applicable verify that grading is not more that 2' from existing to proposed. 23. If you would like to meet with me to review the comments please call to set up an appointment. 24. Add grading note: "Depress all landscaped areas a maximum of 6" for water harvesting" If you have any questions, I can be reached at 520-837-4928 or Bianca.Ramirez@tucsonaz.gov Bianca C. Ramirez Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4928 office (520) 879-8010 fax |
| 12/06/2007 | ANDREW CONNOR | NPPO | REVIEW | Passed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/16/2008 | GERARDO BONILLA | OUT TO CUSTOMER | Completed |
| 01/16/2008 | SUE REEVES | REJECT SHELF | Completed |