| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/02/2008 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Denied | DATE: January 4, 2007 SUBJECT: Grading Plan TO: Fast Permits LOCATION: 3320 N Country Club, T13S, R14E, Section 36, Ward 28 REVIEWERS: Bianca Ramirez, CFM ACTIVITY: T07BU02282 (Second Review) RESUBMITTAL REQUIRED: Grading Plan SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed grading plan for the above referenced property. Engineering Division does not recommend approval of the grading plan at this time. Please address the following review comments prior to the next submittal. Grading Plan: 1. Include a response letter to the comments along with the corrected copies of the Grading Plan. 2. Complied 3. Complied 4. Complied 5. Complied 6. Complied 7. Site visibility triangles are to start at edge of curb and back 20'. Per plan minimum 20' setback does not appear to be met. 8. Complied 9. Complied 10. Provide site plan and grading plan activity numbers on the lower right hand corner of each sheet. Provide the activities numbers on sheet 2 and 3. 11. Location map shows NTS and also indicates 3" = 1 mile. Location map is to be at a scale of 3" = 1 mile. 12. Complied 13. Indicate on grading plan Cut = 0 Cubic Yards. 14. Dimension Right of way and label existing and future right of way. Existing right of way appears to be 60' - 49' and the future right of way appears to be 100'. 15. Complied 16. Provide labels for dimensions from street monument lines to existing and proposed curbs, sidewalks, driveways and utility lines. 17. Provide benchmark based on City of Tucson Datum, Including City Field Book and page number. 18. Complied 19. Complied 20. Complied 21. On sheet 1, clarify types of scuppers and provide detail in detail B. If scupper is roof scupper clearly indicate by labeling as such. 22. Complied 23. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information. 24. Placement of fill in excess of 2' above existing grade at any location in the outer 100' of the developing site is not allowed and/or shall meet the requirements per D.S. 11-01. Provide zoning designation for adjacent properties. Be advised that there may be differential grading requirements based on what has been shown on plans. For N Country Club Rd and Cardi Blvd provide zoning across the street. 25. Drainage patterns with percent slopes and use arrows to indicate direction of slope. Ponding may be a concern. Clearly indicate that water will not be ponding in parking areas 17, 18 and 19. Depressed curbs may be considered to allow any water to enter adjacent landscape area. 26. Provide rates within and adjacent to site to show drainage scheme. Call out peak discharges entering and exiting the site on the site plan and in the location of the called out discharge. 27. 5' sidewalk required for pedestrian access around building. Clearly indicate that pedestrian access has been provided. 28. Verify that all text in a minimum of 12-point font for recordation purposes. 29. Per grading plan sidewalk adjacent to parking appears to be flush with pavement. Truncated domes required along areas where pedestrian circulation area and vehicular areas are adjacent. 30. Additional comments may be forthcoming. Note that the purpose of the grading plan is for inspectors to utilize the plans during their inspection. Specific plan information is needed to ensure that the inspector has the adequate information they need to provide the inspection. The grading plan and site plans are often separated on a construction project and therefore, both need to have the information required for the inspector to complete the inspection. If you have any questions, I can be reached at 837-4928 or Bianca. Ramirez@tucsonaz.gov Bianca Ramirez Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837 - 4928 office (520) 879 - 8010 fax |
| 12/12/2007 | MICHAEL ST. PAUL | ZONING | REVIEW | Denied | December 12, 2007 Development Services Department Zoning Review Section Michael St.Paul Planning Technician T07BU02282 Grading Plans for T07CM02466 3320 North Country Club Road Comments: 1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed. 2. It appears that the grading plan matches the site plan and that all comments for Zoning Review have been successfully addressed. 3. Zoning will re-review the grading plan on the next submittal to ensure compliance with the approved development plan. Additional comments may be forthcoming. |
| 12/17/2007 | ANDREW CONNOR | NPPO | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/10/2008 | THAUSER1 | OUT TO CUSTOMER | Completed |
| 01/10/2008 | SHANAE POWELL | REJECT SHELF | Completed |