Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T07BU02259
Parcel: 135074560

Review Status: Completed

Review Details: GRADING

Permit Number - T07BU02259
Review Name: GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/07/2007 DAVID RIVERA ZONING REVIEW Denied 11/07/07

Development Services Department
Zoning Review Section

David Rivera
Principal Planner

Comments:

1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan on this review.

2. Zoning could not verify that the grading plan was in compliance with the approved development plan. Please submit two copies of the CDRC approved and stamped development, landscape, and NPPO plans with the next grading plan submittal.

3. Please ensure that the grading plan matches the CDRC approved and stamped development plan.

4. Zoning will re-review the grading plan on the next submittal to ensure compliance with the CDRC approved development plan. Additional comments may be forthcoming.
11/08/2007 ANDREW CONNOR NPPO REVIEW Denied Submit a copy of the approved development plan including landscape and native plant preservation plans for reference. The grading application will be reviewed for compliance only when the approved documents are included in the submittal. Revise grading plans as necessary to comply with the approved plans.
12/04/2007 LOREN MAKUS ENGINEERING REVIEW Denied DATE: December 7, 2007

To: Greg Carlson
Greg Carlson Engineering, LLC
1521 E Broadway Blvd
Tucson, Arizona 85719

FROM: Loren Makus
Engineering Division

SUBJECT: ANEWCO
Grading Plan T057BU02259 (First Review)
T14S, R15E, Section 21

RESUBMITTAL REQUIRED: Grading Plan, Drainage Report and SWPPP

The Grading Plan (GP), and Stormwater Pollution Prevention Plan cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Grading Plan:

1. Please include a response letter to the comments along with the corrected copies of the GP.
2. Add note: "Depress all landscaped areas a maximum of 6" for water harvesting"
3. Add the following notes to the grading plan notes:

· "The contractor shall remove the fine materials from the bottom of the detention/retention basin and scarify the basin bottom once the construction activities are completed in order to remove any fine material build up caused by construction and to restore soil percolation."

· "Any engineering work to be done below grade (i.e. toe-downs, cutoff walls, drainage pipes/structures, etc.) shall not be back filled until Development Services Inspector inspects the work and approves it."

4. List administrative address/site address on plans.
5. List all Cut and Fill quantities in cubic yards. If both are 0 cy, please list. Also indicate the area of disturbance in acres or square feet on the grading plan.
6. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information once site and grading plans have been approved.

Stormwater pollution prevention plan:

1. Show, on the site map, directions of stormwater flow (e.g., use arrows to show which ways stormwater will flow) and approximate slopes anticipated after major grading activities. (Part IV.C.3.a)
2. Show, on the site map, locations of structural and nonstructural controls identified in the SWPPP. (Part IV.C.3.c)
3. Show, on the site map, locations where stormwater discharges to a surface water (including ephemeral waters or dry washes) and to MS4s. (Part IV.C.3.g)
4. Provide a note specifying that any concrete washout location will comply with the Aquifer Protection Program General Permit. (Arizona Administrative Code R18-9-B301.L)
I am willing to review the resubmittal over the counter. Please send me an email to set up an appointment.

If you have any questions, I can be reached at 520.837.4927 or loren.makus@tucsonaz.gov
Loren Makus, EIT
Senior Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 837-4927
(520) 879-8010 fax
C:/Address Grading

Final Status

Task End Date Reviewer's Name Type of Review Description
12/10/2007 CINDY AGUILAR OUT TO CUSTOMER Completed
12/10/2007 CINDY AGUILAR REJECT SHELF Completed