Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL-BLDG/FIRE/ZONING/ENG
Permit Number - T07BU02166
Review Name: COMMERCIAL-BLDG/FIRE/ZONING/ENG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/14/2007 | RONALD BROWN | BUILDING-COMMERCIAL | REVIEW | Denied | 1. SOIL BEARING NOTE 7 ON S1 DISAGREES WITH STRUCTURAL CALCULATIONS NOTE INDICATING 1000 PSF. 2. 'LATERAL ANALYSIS' INDICATES 3 LEVELS @ 4500 #/LEVEL (PAGE 10), NOT ACTUAL DESIGN. 3. 'LATERAL ANALYSIS' INDICATES 3 LEVELS @ 5000 #/LEVEL (PAGE 40), NOT ACTUAL DESIGN. 4. CALCULATIONS FOR ADEQUACY OF CONCRETE SLAB UNDER NEW PALLET LOADS ARE MISSING. 5. CALCULATIONS FOR ADEQUACY OF SOIL UNDER NEW PALLET LOADS ARE MISSING. |
| 11/15/2007 | DAVE MANN | FIRE | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/21/2007 | GERARDO BONILLA | OUT TO CUSTOMER | Completed |
| 11/21/2007 | GERARDO BONILLA | REJECT SHELF | Completed |