Review Date Reviewer's Name Type of Review Description Status Comments
05/15/2008 BIANCA RAMIREZ ENGINEERING REVIEW Denied 20 MAY 2008
T07BU01865/GRADING PLAN FOR M & B MECHANICAL
REVIEWED BY RON BROWN
ACCESSIBLE REVIEW
2006 IBC/ICC 117.1
DENIED: SEE COMMENTS BELOW

A. DENOTE GOVERNING ACCESSIBILITY CODE; 2006 IBC/ICC 117.1 FOR PRIVATE PROPERTY
B. DENOTE RIGHT OF WAY ACCESSIBILITY STANDARDS; COT DOT STANDARDS FOR CURB RAMPS AT DRIVE WAYS. STANDARD DETAIL 207 IS FOR R.O.W. RAMPS ONLY. 2006 IBC/ICC 117.1, SECTIONS 405 AND 406 IS FOR PRIVATE PROPERTY CURB AND SIDE WALK RAMPS.
C. PROVIDE AND IDENTIFY ACCESSIBLE ROUTE THROUGHOUT SITE TO ALL BUILDING ENTRANCES AND EXITS AND PARKING FACILITIES AND TO NEAREST PUBLIC TRANSPORTATION POINT AS PER ICC 117.1, SECTION 402
1. SHOW LOCATION OF NEAREST PUBLIC TRANSPORTATION DROP OFF POINT.
2. PROVIDE SPOT GRADES THROUGH OUT ACCESSIBLE ROUTE FINISHED SURFACES OR BY OTHER MEANS TO REASONABLY SHOW COMPLIANCE WITH SLOPES AS REQUIRED BY ICC 117.1, SECTION 403.3
D. ACCESSIBLE PARKING:
1. PROVIDE ONE VAN ACCESSIBLE PARKING SPACE AS PER 2006 IBC, SECTION 1106.5; ICC 117.1, SECTION 503. LARGE SCALE DETAILS NEED TO SHOW ACCESSIBLE ROUTE AND GRADE SLOPES.
a. SHOW "VAN ACCESSIBLE" SIGN ON SIGN DETAIL
2. SURFACE SLOPES FOR ALL ACCESSIBLE PARKING AREAS TO BE NO GREATER THAN 1:48, ICC 117.1, SECTION 502.5. PROVIDE SPOT GRADES REFLECTING COMPLIANCE.
3. ALL ACCESSIBLE PARKING SPACES, PRIVATE PROPERTY SIDE WALK RAMPS AND CURB RAMPS AND RAISED MARKED CROSSINGS TO MEET 2006 IBC/ICC 117.1 ACCESSIBLE STANDARDS, SECTION 405 AND 406. PROVIDE LARGE SCALE DETAILS OF EACH DIFFERENT TYPE SHOWING SIZE OF SPACE AND ISLE, SIGNAGE, ACCESSIBLE ROUTE AND GRADE SLOPES. PROVIDE DETECTABLE WARNINGS AS PER SECTION 406.2. SHOW ALL DETAILS SPECIFIC TO SITE DEVELOPMENT PLAN LAYOUT, NOT A-TYPICAL PLAN LAYOUTS.
E. AT THE CONCRETE WALK CONNECTION TO THE PUBLIC R.O.W. WALKWAY AT THE NORTHWEST CORNER OF THE PROPERTY, MOVE THE CONNECTION WALK TO THE WEST SO AS NOT TO INTERFEAR WITH THE CURB RAMP SLOPE.
F. SHADED AREA PARALLEL WITH FRONT OF BUILDING TO BE A MIN 4' RAISED CONCRETE ACCESSIBLE WALKWAY WITH 6" HIGH CURB.
1. DELETE ALL DETECTABLE WARNINGS SHOWN IN THIS SHADED AREA.
G. PROVIDE ATTACHED 8' WIDE WEDGE CURB IN FRONT OF EACH OVERHEAD DOOR, ATTACHED TO THE CURB FACE.
1. PROVIDE A REMOVABLE 8' LONG BY 36" HIGH RAILING IN FRONT OF WEDGE CURB WITH A "NO PARKING" SIGN ATTACHED.
H. PROVIDE A SIDEWALK RAMP ON THE WEST SIDE OF THE ACCESSIBLE PARKING AISLE
I. SHOW BUILDING MOUNTED ACCESSIBLE PARKING SIGN MOUNTED TO THE BUILDING FACE, 7' A.F.G.
J. REPEAT THE LANDSCAPE PLANTER BOX ADJACENT TO THE WEST SIDE OF THE LOADING ZONE THUS REDUCING THE WIDE OF THE ACCESS AISLE TO THE DUMPSTER. MOVE THE 5' WIDE MARKED CROSSING 5' TO THE WEST. PROVIDE DETECTABLE WARNINGS AT BOTH ENDS OF THE MARKED CROSSING. THE SOUTH DETECTABLE WARNING TO BE IN THE EDGE OF THE 6" CURB
1. PROVIDE A SIDE WALK RAMP PARALLEL WITH THE BUILDING JUST BEFORE THE MARKED CROSSING AT THE EASTERLY MOST PARKING SPACE.
2. PROVIDE A SIDEWALK RAMP ON THE EAST SIDE OF THE BUILDING JUST BEFORE TURNING AT THE FRONT OF THE BUILDING.

END OF REVIEW

DATE: April 20, 2008
SUBJECT: Grading Plan for M&B Mechanical
TO: Southwestern Consulting Engineering, Attention: Steve Wollerman,
LOCATION: 1101 S Santa Rita Avenue
REVIEWER: Bianca Ramirez, CFM
ACTIVITY NUMBER: T07BU01865 (Third Review)


SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed grading plan (1st Review) for the above referenced property. Engineering Division does not recommend approval of the site plan at this time. The following items must be revised or added to the grading plan. Please include a response letter with the next submittal that states how all comments have been addressed.

RESUBMITTAL REQUIRED: GRADING PLAN


1. Please include a response letter to the comments along with the corrected copies of the Grading Permit.

2. Complied

3. The Development Plan is currently in review. Any changes made to the Development Plan must be reflected on the Grading Plan. The Development Plan and Grading Plan must match. Changes have been made internally to ADA - development plan revisions will be required.

4. Complied

5. Complied

6. Complied

7. Complied


8. Complied

9. Complied

10. A permit or a private improvement agreement will be necessary for any work performed in the right-of-way. Contact (520) 791-5100 for permit information.

Complied

11. Complied

12. At northwest corner of parcel truncated domes are present. These truncated domes are not needed in this location. Please remove. Looking north going east there is a stripped 4' pedestrian walkway. 4' sidewalk required. In addition, barriers need to be located between sidewalk and PAAL with either wheel barriers or curb. Looking north going west there is a landscape area with no warning address by adding curb or explain. See comments by Ron Brown included above engineering comments.

13. Complied

14. Complied

15. Per detail (E) existing proposed location of truncated domes not required because transition is onto sidewalk. Truncated dome required from parking area to sidewalk. See detail (E) on grading plan G1.3 for redlines. See comments by Ron Brown.

16. At northeast corner of building, proposed sidewalk shows ramp and truncated domes. Installation of sidewalk may require relocation of ramp and truncated domes. See comments by Ron Brown.

17. Complied

18. Complied

19. Complied

20. Complied

21. Revise Detail H to show R=42' and R = 27.8' per ASHTO - Geometric Design of Highways and Streets - Figure II-2. Minimum turning path for SU design vehicles. Modify radius located within the eastern portion of detail.

22. Complied

23. Complied

24. Complied

25. Complied

26. Complied

27. Add a general note; Call for a Pre-construction meeting prior to start of earthwork. To schedule a DSD Pre-construction meeting, SWPPP inspection or general Engineering Inspections, call IVR (740-6970), or schedule with a Customer Service Representative at the Development Services Department, or contact DSD Engineering at 791-5550 extension 2101, or schedule inspections online at: http://www.ci.tucson.az.us/dsd/Online_Services/Online_Permits/online_permits.html

28. Complied

29. Complied.

30. Please note that subsequent comments may be necessary upon resubmittal, depending on the nature and extent of revisions that occur to the plans.

Bianca C. Ramirez, CFM
Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 837-4928 office
(520) 879-8010 fax
C:/8178 E. 22nd St. Site
05/20/2008 DAVID RIVERA ZONING REVIEW Denied 05/20/2008

Development Services Department
Zoning Review Section

David Rivera
Principal Planner

Comments:

1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan at this time.

2. While zoning acknowledges that the grading plan is in substantial zoning compliance as it relates to the Zoning review purview, with the approved development plan, the grading plan cannot be approved at this time.

3. Based on the ADA review done by the structural reviewer it appears a revised development plan may be required. Please review the ADA comments that have been made by Ronald Brown and address as required. As indicated a revised DP may be required. If so, copies of the approved and stamped revised DP and landscape plans must be resubmitted with the grading plan.