09/17/2007 HEATHER THRALL ZONING REVIEW Denied Zoning will continue the review of the grading plan once the site plan has been approved and engineering and landscape approve the grading plan.
09/20/2007 JASON GREEN ENGINEERING REVIEW Denied DATE: September 20, 2007
SUBJECT: 949 W Silverlake Road Grading Plan- 2nd Engineering Review
TO: Andrew Ogas
LOCATION: T14S R13E Sec23 Ward 1
REVIEWERS: Jason Green, CFM
ACTIVITY: T07BU01624 (Grading Plan)

SUMMARY: Engineering Division of Development Services Department has received and reviewed the revised grading plan (T07BU01624), Drainage Report (INDEVCO Engineering, LLC, 18JUN07 revised 26JUL07), Erosion Hazard Assessment and Setback Reduction Analysis (Tetra Tech, Inc., 04SEP07), Geotechnical Engineering Report (LMT Engineering, Inc., 20NOV06) and Stormwater Pollution Prevention Plan (INDEVCO Engineering, LLC, 30JUL07, revised 10SEP07) for the above referenced property. Engineering Division does not recommend approval of the grading plan at this time. The drainage report was reviewed for grading plan purposes only. The following items need to be addressed:

GRADING PLAN COMMENTS:

1) DS Sec.2-02.2.1.A.15: Revise Detail 3 on Sheet C-6 to provide the dimension for the concrete cut off wall at the proposed headwall location. Per Standard Detail 313 the cut off wall must be dimensioned on the construction plans.

2) DS Sec.2-02.2.1.A.8: Revise the grading plan to call out the minimum 3-foot radii at all back-up spur locations.

3) Provide a cross-section with detail for the transition of the rock riprap into the existing concrete headwall located along the north property line. Provide spot elevations to ensure positive drainage.

4) Review and approval from TDOT Permits and Codes for all improvements within the public right-of-way will be required. A right-of-way use permit application will be required prior to construction. Refer to the following links for TDOT Forms and applications:

a) http://www.tucsonaz.gov/dsd/Forms_Fees___Maps/Applications/applications.html /
b) http://www.dot.ci.tucson.az.us/engineering/pia.php
c) Or contact Steve Tineo at 741-3115 for all additional questions regarding r-o-w.

GENERAL COMMENTS:

Please provide revised grading plan that address the comments provided above. For expedite purposes the grading plan can be reviewed over the counter for stamp approval once all items have been addressed.

If you have any questions, or to schedule an appointment, I can be reached at 837-4929.


Jason Green, CFM
Senior Engineer Associate
Engineering Division
COT Development Services
09/21/2007 ANDREW CONNOR NPPO REVIEW Approved