Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T07BU01479
Parcel: 11604120A

Review Status: Completed

Review Details: REVISION - GRADING

Permit Number - T07BU01479
Review Name: REVISION - GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/07/2009 JASON GREEN ENGINEERING REVIEW Denied DATE: July 7, 2009
SUBJECT: 3141 W Ironwood Hill Dr Site Plan- Engineering Review
TO: Metro Permits Express Attn: Lisa Bowers
LOCATION: T14S R13E Sec05 Ward 1
REVIEWERS: Jason Green, CFM
ACTIVITY: T07CM02890 (Site Plan) and T07BU01479 (Grading Plan) Revisions


SUMMARY: Engineering Division of Development Services Department has received and reviewed the revised site plan (T07CM02890) and grading plan (T07BU01479) for the above referenced property. Engineering Division does not recommend approval of the site plan or grading plan revisions at this time. The following items need to be addressed:

SITE PLAN COMMENTS:

1) Revise Keynote # 57 or provide in plan view the invert elevation and top of manhole elevation for the proposed manhole within the public right-of-way.

2) Revise detail 2/g2.0 to label the required scuppers under the pedestrian circulation area. Provide a reference to a Standard Detail for Public Improvement for the type of scupper proposed. Per the last approved grading plan a Type 2 scupper was required.

GRADING PLAN COMMENTS:

3) Provide a revised grading plan sheet (C1.0) that reflects all proposed changes that are on the revised site plan. Specifically the revised area adjacent to the handicap parking. The grading plan sheet does not reflect the site plan revisions.

4) Provide the docket and page numbers for both new 15-foot Electrical easements per the revised site plan. Docket 13258 Page 3040 and Docket 13332 Page 4428.

5) Provide the invert elevation and top of manhole elevation for the proposed manhole (Keynote #48) within the public right-of-way. All elevation for grading purposes must be shown.

6) Provide the invert elevations for the proposed clean outs (Keynote #62) as shown on the revised plan sheet. All elevation for grading purposes must be shown.

7) Clarify that the proposed 2- 6 inch PVC pipes (Keynote #36) under the pedestrian circulation area is capable of conveying the 10 year flow event. Per the last approved grading plan this area required a Type 2 sidewalk scupper, clarify.

8) Clarify the bubbled revision extending thru the PAAL on the east side of the building.

GENERAL COMMENTS:

Please provide a revised site plan and grading plan sheet that addresses the comments provided above. Include a comprehensive response letter addressing in detail responses to all of the above comments. Enclose "redlines" with the resubmittal package.

For questions or to schedule an appointment I can be reached at 837-4929.


Jason Green, CFM
Senior Engineer Associate
Engineering Division
COT Development Services
07/07/2009 STEVE SHIELDS ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: T07BU01479
Grading Plan (Revision)

TRANSMITTAL DATE: July 6, 2009

1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed.

2. The handicapper parking are shown on the grading plan does not match the handicapped parking area shown on the site plan.

3. Zoning could not verify that the grading plan was in compliance with the approved site plan. Please submit two copies of the approved and stamped site, landscape, and NPPO plans with the next grading plan submittal.

4. Zoning will re-review the grading plan on the next submittal to insure compliance with the approved and stamped site plan. Additional comments may be forthcoming.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956

C:\planning\grading\t07bu01479

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Approved site plans and additional requested documents

Final Status

Task End Date Reviewer's Name Type of Review Description
07/14/2009 CINDY AGUILAR OUT TO CUSTOMER Completed
07/14/2009 SUE REEVES REJECT SHELF Completed