Review Date Reviewer's Name Type of Review Description Status Comments
07/30/2007 ANDREW CONNOR NPPO REVIEW Denied Site plan approval is necessary to continue review.
08/03/2007 HEATHER THRALL ZONING REVIEW Denied Zoning will continue the review of the grading plan on the resubmittal to compare with the revised site plan.
08/27/2007 JASON GREEN ENGINEERING REVIEW Denied DATE: August 28, 2007
SUBJECT: 3141 W Ironwood Hill Dr Site Plan- Engineering Review
TO: Metro Permits Express Attn: Lisa Bowers
LOCATION: T14S R13E Sec05 Ward 1
REVIEWERS: Jason Green, CFM
ACTIVITY: T07CM02890 (Site Plan) and T07BU01479 (Grading Plan)


SUMMARY: Engineering Division of Development Services Department has received and reviewed the site plan (T07CM02890), grading plan (T07BU01479), and Drainage Report (DOWL Engineers, 06JUN07) for the above referenced property. Engineering Division does not recommend approval of the site plan or grading plan application at this time. The following items need to be addressed:


SITE PLAN COMMENTS: Provide all information associates with the site plan content on one sheet. The submittal package includes two site plans, one stamped by an architect and one stamped by the civil engineer. The information provided on both plans needs to be combined for one overall site plan document. Engineering tried to review both sheet for conformance, but could not verify if all the information was included because of the back and forth review, Sheet C1.0 was reviewed for Engineering requirements.

1) DS Sec.2-02.2.1.A.4: Verify 12-point font for the project location map on Sheet C1.0. The location map on Sheet g2.0 does not conform to the location map requirements.

2) DS Sec.2-02.2.1.A.8: Verify that the site plan shows wheel stop barrier for the parking spaces located along any adjacent landscape areas and/or pedestrian circulation paths. The barriers are to be set at 15.5-feet to accommodate the required 2.5-foot overhang to prevent encroachment or damage to the proposed landscape area and the required clear 4-foot pedestrian path.

3) DS Sec.2-02.2.1.A.8: Verify on the site plan the PAAL intersection from existing to proposed. Sheet C1.0 shows a separation with curbing which does not agree with Sheet g2.0.

4) DS Sec.2-02.2.1.A.11: Depict and label the 25-feet radii concrete curbs per City of Tucson/Pima County Standard Detail 213 (PC/COT SD 213) at the driveway entrance off of Ironwood Hill Drive. The curbs should be constructed at the edge of pavement, which must also be depicted on the site plan. Curb returns must be constructed entirely within the subject parcel. Refer to DS Sec.3-01.3.2.C and the Transportation Access Management Guidelines for street development standards.

5) DS Sec.2-02.2.1.A.11: Depict and label the 18-feet radii concrete curbs per City of Tucson/Pima County Standard Detail 213 (PC/COT SD 213) at the driveway entrances off of Cosby Avenue. The curbs should be constructed at the edge of pavement, which must also be depicted on the site plan. Curb returns must be constructed entirely within the subject parcel. Refer to DS Sec.3-01.3.2.C and the Transportation Access Management Guidelines for street development standards.

6) DS Sec.2-02.2.1.A.11: Verify with dimensions that all PAALs meet the minimum width requirement of 24-feet, specifically at all PAAL curvatures and PAAL intersections.

7) DS Sec.2-02.2.1.A.11: Verify on the site plan, with a dimension, the minimum setback from any existing light pole, fire hydrants, catch basins, etc for the proposed driveway entrance. Refer to the Transportation Access Management Guidelines for minimum setback requirements for the driveway.

8) DS 3-05.2.2.B.3: Provide the required 2-foot separation from the PAAL to the property line and the CMU wall on the south portion of the property.

9) DS Sec.2-02.2.1.A.12: Verify that all handicap access ramps meet the design requirements per ANSI Standards A117.1-2003 Section 406.13. The location of the truncated domes must be at the transition of the pedestrian circulation to vehicular circulation for all existing and proposed ramps.

10) DS Sec2-02.2.1.A.12: Provide the required 6-foot wide sidewalk along the street frontage of Ironwood Hills Drive. Provide a dimension on the site plan to show the 6-foot width. Per the adopted Mayor and Counsel policy all sidewalks along MS&R right-of-ways for arterial and collector streets require 6-foot wide sidewalks. If a sidewalk already exist along the frontage of Ironwood Hill Drive provide photo documentation showing that the existing sidewalk is in good condition. If the sidewalk is missing in spots or is cracked and buckled a new 6-foot sidewalk will be required.

11) DS Sec.2-02.2.1.A.12: Provide the required 5-foot sidewalk along the street frontage of Cosby Avenue. All new development requires a new 5-foot sidewalk per DS Sec.3-01.3.3.A.

12) DS Sec.2-02.2.1.A.12: Revise the site plan to show the required pedestrian circulation path that is required from the proposed vehicular use area along the southern portion of the lot to the proposed buildings.

13) DS Sec.2-02.2.1.A.12: Revise the site plan to provide the required pedestrian circulation path from the proposed and existing building to the refuse enclosure located in the east vehicular use area. All transitions from vehicular use to pedestrian use areas must have truncated domes.

14) DS Sec.2-02.2.1.A.17: A grading plan application has been submitted for this project due to the cut and fill quantities shown on Sheet C1.1. The grading plan can not be approved prior to site plan approval.

15) DS Sec.2-02.2.1.A.19: Provide the recordation information for the right-of-way on Cosby Avenue as dimensioned on the site plan.

16) DS Sec.2-02.2.1.A.19: Revise the site plan to label the shown right-of-way as dimensioned on the site plan for Ironwood Hill Drive as existing and/or future.

17) DS Sec.2-02.2.1.A.19: Revise the site plan to label Ironwood Hill Drive as an "MS&R Road and a Scenic Corridor."

18) DS Sec.2-01.2.1.A.20: Verify that all existing and proposed easements are drawn with recordation information, location, width, and purpose of on the site plan.

19) DS Sec.2-01.2.1.A.21: Provide dimensions from the street monument lines to the existing and/or proposed curb, sidewalk, driveway and any utility lines.

20) DS Sec.2-02.2.1.A.32: Revise the trash enclosure location and/or site plan to show the required 14-foot x 40-foot clear approach for all refuse container locations. Provide 45 or 30 degree angles if necessary. Refer to DS Sec.6-01 for all refuse requirements.

21) Review and approval from TDOT Permits and Codes for all improvements within the public right-of-way will be required. A right-of-way use permit application will be required prior to construction. Refer to the following links for TDOT Forms and applications:

a) http://www.tucsonaz.gov/dsd/Forms_Fees___Maps/Applications/applications.html /

b) http://www.dot.ci.tucson.az.us/engineering/pia.php

c) Or contact Steve Tineo at 741-3115 for all additional questions regarding r-o-w.

22) Be advised that further comments may be forth coming on resubmittal of the site plan and grading plan.


GRADING PLAN COMMENTS: Sheet C1.1 was reviewed for grading plan purposes, however until all site plan comments are addressed the grading plan could not be shown to be in conformance with an approved plan.

23) DS Sec.11-01.9: Revise the grading plan to provide the required 2-feet setback from the west property boundary to the toe of fill slope for the proposed basin located at this location. Provide cross-sections on the grading plan to show the limits of grading and the required 2-feet setback from all property lines.

24) Provide the referenced soils investigation report, General Note # 4, prepared by Western Technologies, Inc. for the proposed site.

25) Please ensure that any future grading plan will be consistent with the site plan and Drainage Report. Grading standards may be accessed at: http://www.ci.tucson.az.us/dsd/DevStandsTOC.pdf

26) DS Sec.11-01.4.1.C.4: Provide a General Note stating that all CMU walls and retaining walls will require a separate permit for review and approval by all necessary Development Services Departments.

27) Provide a general note on the grading plan to state the following; "Call for a Pre-construction meeting prior to start of earthwork. To schedule a DSD Pre-construction meeting, SWPPP inspection or general Engineering Inspections, call IVR (740-6970), or schedule with a Customer Service Representative at the Development Services Department, or contact DSD Engineering at 791-5550 extension 2101, or schedule inspections online at: http://www.ci.tucson.az.us/dsd/Online_Services/Online_Permits/online_permits.html

28) Arizona Pollutant Discharge Elimination System (AZPDES) requirements are applicable to this project. Stormwater Pollution Prevention Plans (SWPPP) and text addressing stormwater controls for all areas affected by construction activities related to this development will be required with the revised grading plan submittal. For further information, visit www.adeq.state.az.us/environ/water/permits/stormwater.html.


DRAINAGE REPORT:

29) DS Sec.10-01.2.2: Provide the referenced soils investigation report (grading plan General Note #4) with building setbacks from the proposed basins, infiltration rates for the retention basins, and slope stability recommendations for basin design and slope stability. Clarify if the Drainage Report and site/grading plan match the soils investigation report.

30) Provide a revised Drainage Report to state that the 10-year flood flow is contained under the sidewalk at all scupper concentration points. Provide details and dimensions in plan view for the scuppers on the proposed site plan.


GENERAL COMMENTS:

Please provide a revised site plan, Drainage Report, grading plan and soils investigation report that addresses the comments provided above. Include a comprehensive response letter addressing in detail responses to all of the above comments. Enclose "redlines" with the resubmittal package.

Further comments may be generated upon resubmittal of the site plan, Drainage Report, grading plan and soils investigation report reviews.

If you have any questions, or to schedule an appointment, I can be reached at 837-4929.



Jason Green, CFM
Senior Engineer Associate
Engineering Division
COT Development Services