Permit Number: T07BU01394
Parcel: 12514045E

Review Status: Completed

Review Details: WALLS SUBMITTAL

Permit Number - T07BU01394
Review Name: WALLS SUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/28/2007 RBROOKS1 BUILDING-COMMERCIAL REVIEW Denied 1. REVIEW OF THE WALL AND FOOTING DESIGNS COULD NOT BE COMPLETED DUE TO THE SUBMITTAL OF AN INCOMPLETE SET OF PLANS. pLEASE PROVIDE A COMPLETE SET OF CALCULATIONS VERIFYING THAT THE DERIVATION OF THE WIND PRESSURE IS IN ACCORDANCE WITH ASCE 7-05 SECTION 6.5.14

FOOTING TOP REINFORCEMENT SHOULD BE INSTALLED IN SECTION 3/S5 FOR LOADS ACTING TO THE RIGHT. REFERENCE IBC SECTION 1604.4

Final Status

Task End Date Reviewer's Name Type of Review Description
08/29/2007 VFLORES1 OUT TO CUSTOMER Completed