Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - GRADING ALL
Permit Number - T07BU01378
Review Name: RESUBMITTAL - GRADING ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/30/2007 | ANDREW CONNOR | NPPO | REVIEW | Approved | |
| 11/06/2007 | DAVID RIVERA | ZONING | REVIEW | Approved | |
| 12/10/2007 | PAUL MACHADO | ENGINEERING | REVIEW | Denied | To: Steve Wollerman DATE: December 11, 2007 South Western Consulting Engineers, LLC 435 E. 9th Street Tucson, Arizona 85705 SUBJECT: 9089 E. Camino Abril Grad lot 21 Grading Plan T07BU01378 (Second Review) T14S, R15E, Section 27 RESUBMITTAL REQUIRED: Grading Plan. The Grading Plan (GP) cannot be approved as submitted. Please address the following review comments prior to the next submittal. Grading Plan: 1. Please include a response letter to the comments along with the corrected copies of the GP. 2. Show refuse container location, size, and access thereto fully dimensioned per D.S. 2-02.2.1.32 and D.S. 6-01.0. The position of the refuse enclosure indicates that the service vehicle will have to reverse on a curve to exit the property. A straight distance allowed of 40' maximum in reverse to exit the property. Revise as required. 3. Show refuse container location, size, and access thereto fully dimensioned per D.S. 2-02.2.1.32 and D.S. 6-01.0. The refuse enclosure is properly dimensioned, however, access to the dumpter does not meet COT standard. See comment no. 2. 4. An hourly review fee for the third grading plan submittal and review may be accessed depending on the correctness of the revisions. All third submittals will charged an hourly review rate of $75.00 per City of Tucson Development Services Department. Drainage report: 1. The DR has been accepted by Engineering. Re-submit the DR along with the corrected copies of the Grading Plan. Stormwater pollution prevention plan: The SWPPP has been accepted by Engineering. Re-submit the SWPPP along with the corrected copies of the Grading Plan. If you have any questions, I can be reached at 837-4932 or Paul.Machado@tucsonaz.gov Paul P. Machado Senior Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4932 office (520) 879-8010 fax C:/9089 E. Camino Abril Grad lot 21_2 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/14/2007 | SUE REEVES | OUT TO CUSTOMER | Completed |
| 12/14/2007 | SUE REEVES | REJECT SHELF | Completed |