Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - GRADING ALL
Permit Number - T07BU01296
Review Name: RESUBMITTAL - GRADING ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/30/2007 | DAVID RIVERA | ZONING | REVIEW | Denied | Development Services Department Zoning Review Section 11/30/07 David Rivera Principal Planner Comments: 1. The grading plan has been reviewed by Zoning Section comments or concerns have been addressed. While the grading plans appear to be in complaince with the site plan in for review the site plan has not been approved by all DSD reviewers. 2. Zoning could not verify that the grading plan was in compliance with the approved site plan. Please submit two copies of the DSD approved and stamped site, landscape, and NPPO plans with the next grading plan submittal. 3. Zoning will re-review the grading plan on the next submittal to ensure compliance with the approved and stamped site plan. Additional comments may be forthcoming. 4. Label the maximum slope allowed for handicapped parking spaces and access aisle that serves the parking spaces. The maximum slope allowed per ANSI section 503.4 is 1:48 (2%). Label the slope on the handicapped parking space detail and access aisle. 5. Zoning is willing to review and approve the grading plan (if possible) over the counter once the CDRC approved and stamped development plan is included with the next grading plan submittal. Please call in advance for an appointment if this is an option you would like to pursue. Phone 791-5608 ext. 74957 |
| 12/10/2007 | ANDREW CONNOR | NPPO | REVIEW | Needs Review | Include with re-submittal approved landscape plan to verify that all changes to the site plan are reflected on the landscape and grading plans. The application will be reviewed for compliance only when all the approved documents are included with the submittal. |
| 12/11/2007 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Approv-Cond | DATE: December 11, 2007 SUBJECT: Whataburger Site Plan (T07CM02433) and Grading (T07BU01296) TO: Kimley Horne and Associates - Darren Watson LOCATION: 6504 E 22nd Street T14S, R15E, Section 19 REVIEWER: Bianca Ramirez, CFM ACTIVITY NUMBER: T07CM02433 and T07BU01296 (Third Review) SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed Site Plan and Grading Plan for the above referenced property. Engineering Division recommends conditional approval of the Site Plan or Grading Plan at this time. The Site Plan and Grading plan can be approved one revided copy of plans have been submitted with revisions including water harvesting openings, curb returns (25'), wider entrance and recordation information for road. If you have any questions, I can be reached at 837-4928 or Bianca.Ramirez@tucsonaz.gov Bianca C. Ramirez Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4928 office (520) 879-8010 fax |