Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - GRADING ALL
Permit Number - T07BU01082
Review Name: RESUBMITTAL - GRADING ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/02/2007 | ANDREW CONNOR | NPPO | REVIEW | Denied | Submit a copy of the approved site and landscape plans for reference. The grading application will be reviewed for compliance only when the approved documents are included in the submittal. Revise grading plans as necessary to comply with the approved site plan. |
| 08/13/2007 | DAVID RIVERA | ZONING | REVIEW | Denied | 07/02/07 Development Services Department Zoning Review Section David Rivera Principal Planner Comments: 1. Zoning has done a cursory review of the grading plan but cannot approve the plan at this time. The site plan must be cpompletely approved and stamped prior to approval of the grading plan. 2. Zoning could not verify that the grading plan was in compliance with the approved site plan. Please submit two copies of the approved and stamped site, landscape, and NPPO plans with the next grading plan submittal. 3. Zoning will re-review the grading plan on the next submittal to ensure compliance with the approved and stamped site plan. Additional comments may be forthcoming. 4. To assure approval of the grading plan please make sure that teh grading plan matches the approved site plan. |
| 08/30/2007 | JASON GREEN | ENGINEERING | REVIEW | Denied | DATE: August 30, 2007 SUBJECT: New Parking Structure for Mosaic Café Grading Plan Submittal- 2nd Engineering Review TO: Maria Rojas LOCATION: 2625 N Silverbell Rd, T13S R13E Sec33 Ward 1 REVIEWERS: Jason Green, CFM ACTIVITY: T07BU01082 SUMMARY: Engineering Division of Development Services Department has received and reviewed the grading plan and geotechnical report (Pattison-Evanoff Engineering, LLC, 08MAR06). The grading plan is not approved at this time. Please address the following comments: GRADING PLAN COMMENTS: Be advised that grading plan can not be approved prior to Site Plan approval. DS Sec.2-02.2.1.A.14: Per site plan comment # 1: Provide the approved variance for the required maneuvering area for the loading zone that is shown on the revised site plan. Variance must be approved prior to site plan approval which must be approved prior to grading plan approval. GENERAL COMMENTS: Please provide an approved site plan with the approved variance for the loading zone, and a grading plan that matches the approved site plan. For any questions or to schedule a meeting, call me at 837-4929. Jason Green, CFM Senior Engineer Associate Engineering Division Development Services |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/31/2007 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
| 08/31/2007 | SUE REEVES | REJECT SHELF | Completed |