Permit Number: T07BU00684
Parcel: 14042075A

Review Status: Completed

Review Details: REVISION - GRADING

Permit Number - T07BU00684
Review Name: REVISION - GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/16/2008 JASON GREEN ENGINEERING REVIEW Denied DATE: September 16, 2008
SUBJECT: Staybridge Suites Revised Grading Plan- Engineering Review
TO: Kimley-Horn and Associate
LOCATION: 2705 E Executive Dr, T15S R14E Sec17 Ward 5
REVIEWERS: Jason Green, CFM
ACTIVITY: T07BU00684


SUMMARY: Engineering Division of Development Services Department has received the revised grading plan. Engineering Division has reviewed the submitted grading plan and does not recommend approval at this time. The following items need to be addressed:


GRADING PLAN COMMENTS:

1) Revise the grading plan to reflect the revised Development Plan and the conditional approval comments from Environmental Services for the revised refuse containers. The Grading Plan must reflect the following revisions requested by Environmental Services prior to approval:

a) Vertical curb/island directly west of enclosure (Southside) needs to be increased to a minimum 25 ft radius to allow adequate maneuverability for collection vehicle to position itself to and from enclosure area.

b) Sheet 3, Double Dumpster Enclosure - Change spacing of rear post barricades/bollards from 6.7 ft to 4 ft for each container service area and adjust other dimensions accordingly.


GENERAL COMMENTS:

Please provide a revised grading plan at resubmittal that addresses the comments above.

For any questions or to schedule a meeting call me at 837-4929.



Jason Green, CFM
Senior Engineer Associate
Engineering Division
Development Services
09/17/2008 MICHAEL ST. PAUL ZONING REVIEW Denied September 17, 2008

Development Services Department
Zoning Review Section

Michael St.Paul
Planning Technician

T07BU00684R Grading Plans for D06-0040
2705 East Executive Drive

Comments:

1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed. Please provide a copy of the approved grading plan that you are trying to revise.

2. In addition, we could not verify that the grading plan was in compliance with the approved development plan for Zoning Review. Please submit two copies of the approved and stamped Development Plan, Landscape, and NPPO plans with the next grading plan submittal. If the approved Development Plan requires revision the grading plan cannot be approved until the revised Development Plan has been approved.

3. Zoning will re-review the grading plan on the next submittal to ensure compliance with the approved development plan. Additional comments may be forthcoming.
09/22/2008 ANDREW CONNOR NPPO REVIEW Denied Submit a copy of the approved development plan including landscape and native plant preservation plans for reference. The grading application will be reviewed for compliance when the approved documents are included in the submittal.

Final Status

Task End Date Reviewer's Name Type of Review Description
09/29/2008 GERARDO BONILLA OUT TO CUSTOMER Completed
09/29/2008 SUE REEVES REJECT SHELF Completed