Permit Number - T07BU00680
Review Name: RESUBMITTAL - GRADING ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/13/2007 | JASON GREEN | ENGINEERING | REVIEW | Approved | DATE: November 13, 2007 SUBJECT: Desert View Plaza Lot 1-7 Grading Plan- 4th Engineering Review TO: Baker and Associates Engineering, Inc. LOCATION: 6307 S Alvernon, T15S R14E Sec10 Ward 5 REVIEWERS: Jason Green, CFM ACTIVITY: T07BU00680 SUMMARY: Engineering Division of Development Services Department has received and reviewed the revised grading plan, Drainage Report (Baker & Associates Engineering, Inc., 22MAR07, revised 28JUN07, revised 17OCT07), Geotechnical Evaluation (Western Technologies, 2920JX177, with addendum 25JUN07), Stormwater Pollution Prevention Plan (Baker & Associates Engineering, Inc., MAR07, revised JUN07, revised17OCT07), last approved Tentative Plat sheets and the Valencia Road Offsite Public Paving Improvement Plans (approved by Pima County DOT 08NOV07) for the above referenced property. Engineering Division recommends approval of the grading plan at this time. · DS Sec.11-01.4.1.C.3: A post-percolation test from a registered geotechnical engineer will be required prior to the final grading inspection approval and placement of vegetation within the basin specified on the grading plan sheets. · Improvements along Valencia Road must conform to the approved Valencia Road Offsite Public Paving Improvement Plans approved by Pima County Department Of Transportation dated 08NOV07. · Review and approval from TDOT Permits and Codes for all improvements within the public right-of-way will be required. A right-of-way use permit application will be required prior to construction. Refer to the following links for TDOT Forms and applications: a) http://www.tucsonaz.gov/dsd/Forms_Fees___Maps/Applications/applications.html / b) http://www.dot.ci.tucson.az.us/engineering/pia.php c) Or contact Thad Harveston at 741-3115 for all additional questions regarding r-o-w. For any questions call me at 837-4929. Jason Green, CFM Senior Engineer Associate Engineering Division Development Services |
| 11/13/2007 | DAVID RIVERA | ZONING | REVIEW | Approved | |
| 11/16/2007 | ANDREW CONNOR | NPPO | REVIEW | Approv-Cond |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/05/2008 | SUE REEVES | APPROVAL SHELF | Completed |
| 11/05/2008 | VFLORES1 | OUT TO CUSTOMER | Completed |