Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - GRADING ALL
Permit Number - T07BU00558
Review Name: RESUBMITTAL - GRADING ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/01/2007 | STEVE SHIELDS | ZONING | REVIEW | Denied | DSD TRANSMITTAL FROM: Steve Shields Lead Planner PROJECT: Living Interiors - 2332 N. Oracle Road T07BU00558 Grading Plan (3rd Review) TRANSMITTAL DATE: November 01, 2007 1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed. 2. Zoning could not verify that the grading plan was in compliance with the approved site plan. Please submit two copies of the approved and stamped site, landscape, and NPPO plans with the next grading plan submittal. 3. Zoning will re-review the grading plan on the next submittal to insure compliance with the approved and stamped site plan. Additional comments may be forthcoming. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956 C:\planning\grading\t07bu00558 RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Approved site plans and additional requested documents |
| 11/05/2007 | ANDREW CONNOR | NPPO | REVIEW | Denied | Site plan approval is necessary to continue review. |
| 11/27/2007 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Denied | DATE: November 27, 2007 ACTIVITY NUMBER: T07BU00558 PROJECT NAME: Living Interior PROJECT ADDRESS: 2332 North Oracle Road PROJECT REVIEWER: Bianca Ramirez, CFM The following items must be revised or added to the grading plan. Please include a response letter with the next submittal that states how all comments have been addressed. RESUBMITTAL REQUIRED: GRADING PLAN (2nd Review) APPROVED: DRAINAGE REPORT 1. A copy of the stamped approved Site Plan must be included with the Grading Plan submittal. 2. The Site Plan is currently in review. Any changes made to the Site Plan must be reflected on the Grading Plan. The Site Plan and Grading Plan must match. 3. Provided 4. Provided 5. Indicate building downspouts. Add note, "All roof spouts will be routed under any adjacent sidewalk." Graphically indicate downspouts and sidewalk scuppers on grading plan. Show how roof flows will be routed to cisterns for water harvesting on the grading plan for easy reference of inspectors. 6. Provided 7. Provided 8. Provided 9. Modify water-harvesting area to be 6" in depth. Add note: "Depress all landscaped areas a maximum of 6" for water harvesting" 10. From the street centerline of Sahuaro Street and 11th Avenue label the dimension to the existing curb and sidewalk location. DS 2-02.2.1.A.21. 11. Provided. 12. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information. 13. Please note that subsequent comments may be necessary upon resubmittal, depending on the nature and extent of revisions that occur to the plans. 14. Cut or fill slopes require a 2' minimum setback from property line. Indicate area of grading and clearly indicate that minimum 2' setback is being met. 15. Verify that all construction related information is provided on the grading plan for inspector to reference. Specifically, sidewalk widths, curb returns radii. After reviewing grading plan it seems that a lot of the information is available on the site plan. It is not necessary to transfer all of the General notes. 16. Add detail or note: Per Federal ADA requirements, all wheel chair ramps shall have the truncated domes instead of the standard grooves that are shown on COT SD 207. Aside from the Truncated Domes, all wheel chair ramps shall be constructed in accordance with COT SD 207. 17. Additional comments may be forthcoming depending on the information provided on next submittal. If you have any questions, I can be reached at 837-4928 or Bianca. Ramirez@tucsonaz.gov Bianca Ramirez Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837 - 4928 office (520) 879 - 8010 fax |