Permit Review Detail
Review Status: Completed
Review Details: GRADING
Permit Number - T07BU00431
Review Name: GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/20/2007 | ANDREW CONNOR | NPPO | REVIEW | Denied | 1. Each lot within Wildcat Pass must submit a separate NPPO plan. 2. The NPPO shall include an inventory and analysis of all plants listed as Federal Endangered Species, all Saguaros, and all Ironwoods designated as Protected Native Plants according to Sec. 3.8.5. Preservation and mitigation requirements for these genus and species shall conform to Sec. 3.8.6.2. 3. Include the location, size, color, and textural treatment of all retaining walls, riprapped slopes, or other constructed means of slope stabilization must be shown on one (1) of the plans submitted. Vegetation retention and re-vegetation should be used in conjunction with riprapping. 4. Additional comments may apply. |
| 03/20/2007 | DAVID RIVERA | ZONING | REVIEW | Denied | 03/20/07 Development Services Department Zoning Review Section David Rivera Principal Planner Comments: 1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed. The site/building plans will be approved by zoning once the grading plan has been approved by both Engineering and Landscaping sections. This lot is to be developed with barrier free accessiblity from the street sidewalk to the front door. Provide a detail drawing that demonstrates how this requirement is to be accomplished and will be met. The street sidewalk must be drawn and labeled as approved on the tentative plat. 3. Zoning will re-review the grading plan on the next submittal to ensure compliance with the approved and stamped site plan. Additional comments may be forthcoming. |
| 04/24/2007 | ELIZABETH EBERBACH | ENGINEERING | REVIEW | Denied | TO: Bob and Amy Phillips SUBJECT: 1900 S Twinkling Starr Site and Grading Plan Review LOCATION: Lot 46 Wildcat Pass REVIEWER: Elizabeth Eberbach ACTIVITY NUMBERS: T07CM00738, T07BU00431 Summary: Engineering Division has reviewed the site plan and grading plan submittal packages and does not recommend approval at this time. Address the following comments for resubmittal. SITE AND GRADING PLAN COMMENTS: 1) DS Sec.11-01.2.1.A: Site Plan may be labeled as Site/Grading Plan. 2) DS Sec.3-01.4.4.B: Revise cross section and/or provide the following additional cross sections for clarification: a) Provide a section at the extreme cut condition proposed at the north corner of the building pad. This section shall include an interceptor swale at top of slope. Any slopes proposed steeper than 2:1(H:V) shall require support by a geotechnical report. b) Provide a cross section of the proposed driveway with grades, and elevations at the street. 3) DS Sec.11-01.4.1.C.3: Delineate grading limits to show as including the proposed utilities and the limits need to provide for sufficient space for grading construction. It may be necessary to indicate heavy duty construction fence to restrict construction activity along the side yard grading limit boundaries. 4) Indicate grade break location and elevation on plan view for interceptor swale at top of north cut slope. 5) Label material for driveway. 6) Provide a few additional proposed spot elevations in rear of yard and front yards to indicate positive draiange away from foundation and toward drainage focal points. 7) DS Sec.11-01.4.1.C: Address the following General Notes comments: a) To General Note 3, add reference to the City of Tucson Development Standards 11-01 for grading standards. b) Add that the project will comply with City of Tucson Land Use Code Sections 2.8.1 Hillside Development Zone (HDZ). c) DS Sec.11-01.4.1.C: Add note that rip rap slopes shall have handplaced rip rap with filter fabric per HDZ requirements. d) Add the following notes to the plan: i) CALL FOR PRE-CONSTRUCTION MEETING. FOR A DSD ENGINEERING INSPECTION, CALL IVR (740-6970), OR SCHEDULE WITH A CUSTOMER SERVICE REPRESENTATIVE AT THE DEVELOPMENT SERVICES DEPARTMENT, OR CONTACT DSD ENGINEERING AT 791-5550 EXTENSION 2101, OR SCHEDULE INSPECTIONS ONLINE AT: HTTP://WWW.CI.TUCSON.AZ.US/DSD/ONLINE_SERVICES/ONLINE_PERMITS/ONLINE_PERMITS.HTML ii) A COPY OF THE GRADING PLAN AND GRADING PERMIT SHALL BE KEPT AT THE SITE AT ALL TIMES, UNTIL FINAL GRADING APPROVAL. iii) ANY REVISION TO THE GRADING PLAN MAY REQUIRE A RE-SUBMITTAL OF A REVISED GRADING PLAN FOR REVIEW. CONTACT DSD ENGINEERING AT 791-5550 TO DISCUSS CHANGES IN GRADING DESIGN. iv) IF GRADING CONSTRUCTION IS EXPECTED TO LAST LONGER THAN THE EXPIRATION DATE OF THE GRADING PERMIT, CONTACT DSD TO RENEW/EXTEND THE GRADING PERMIT. IF FINAL GRADING INSPECTION HAS NOT BEEN COMPLETED BEFORE THE GRADING PERMIT EXPIRES, AND THE PERMIT HAS NOT BEEN RENEWED, ADDITIONAL FEES AND REVIEWS MAY BE REQUIRED. v) SEPARATE BUILDING PERMIT APPLICATIONS ARE REQUIRED FOR ANY WALLS. vi) THE PERMITEE SHALL NOTIFY THE DSD WHEN THE GRADING OPERATION IS READY FOR FINAL GRADING INSPECTION. FINAL GRADING APPROVAL SHALL NOT BE GIVEN UNTIL ALL WORK, INCLUDING INSTALLATION OF ALL DRAINAGE IMPROVEMENTS AND THEIR PERMANENT PROTECTIVE DEVICES, AND ALL EROSION CONTROL MEASURES HAVE BEEN COMPLETED IN ACCORDANCE WITH THE APPROVED GRADING PLAN AND GRADING PERMIT, AND ALL CONDITIONS OF PERMIT ARE COMPLETED. vii) THERE SHALL BE NO DISTURBANCE OUTSIDE OF THE DISTURBANCE/GRADING LIMITS. 8) For resubmittal, provide 4 copies of the revised Site/Grading Plan and any other supporting documents, with a response letter. I can be reached at 837-4934 if you have questions or would like to set up a meeting to go over resubmittal. Elizabeth Eberbach, PE Civil Engineer Engineering Division Development Services Department |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 05/15/2007 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 05/15/2007 | SUE REEVES | REJECT SHELF | Completed |