Permit Review Detail
Review Status: Completed
Review Details: GRADING
Permit Number - T07BU00403
Review Name: GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/19/2007 | DAVID RIVERA | ZONING | REVIEW | Denied | 03/19/07 Development Services Department Zoning Review Section David Rivera Principal Planner Comments: 1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed. 2. Please address the following zoning comments. a. The grading plan must include the line that represents the 50-foot study area. It appears that the limits of disturbance exceed the limits as depicted on the PPO plan. No construction may occur within the 50-foot study area without review and approval of the special application of the WASH ordinance. If such an application has been processed please submit a copy of the approved and stamped plan with the next submittal package. b. Please verify with the landscape section reviewers about the requirements for a Conservation Easment over a portion of this lot. Provide the required documents for review with the next submittal prior to recordation. 3. Zoning will re-review the grading plan on the next submittal to ensure compliance with the approved and stamped site plan. Additional comments may be forthcoming. |
| 03/20/2007 | ANDREW CONNOR | NPPO | REVIEW | Denied | 1. The grading and NPP plans shall indicate the 50-ft study area, as it appears on the Wash Ordinance Mitigation Plan included with Case # S02-008. Verify that no construction will occur within 50-ft study area. 2. To protect the natural areas, a covenant must be provided with record interest in the natural area in favor of the City of Tucson per LUC 2.8.1.7.D. Submit the required covenant or conservation easement and legal description for review. |
| 03/30/2007 | ELIZABETH EBERBACH | ENGINEERING | REVIEW | Denied | SUBJECT: 2065 S Twinkling Starr Grading Review REVIEWER: Elizabeth Eberbach ACTIVITY NUMBERS: T07CM00660, T07BU00403 Summary: Engineering Division has reviewed the grading/site plan and can not recommend approval at this time. The following comments must be addressed: GRADING PERMIT COMMENTS: 1) Add the following as general notes to Site/Grading Plan. a) CALL FOR PRE-CONSTRUCTION MEETING. FOR A DSD ENGINEERING INSPECTION, CALL IVR (740-6970), OR SCHEDULE WITH A CUSTOMER SERVICE REPRESENTATIVE AT THE DEVELOPMENT SERVICES DEPARTMENT, OR CONTACT DSD ENGINEERING AT 791-5550 EXTENSION 2101, OR SCHEDULE INSPECTIONS ONLINE AT: HTTP://WWW.CI.TUCSON.AZ.US/DSD/ONLINE_SERVICES/ONLINE_PERMITS/ONLINE_PERMITS.HTML b) A COPY OF THE GRADING PLAN AND GRADING PERMIT SHALL BE KEPT AT THE SITE AT ALL TIMES, UNTIL FINAL GRADING APPROVAL. c) ANY REVISION TO THE GRADING PLAN MAY REQUIRE A RE-SUBMITTAL OF A REVISED GRADING PLAN FOR REVIEW. CONTACT DSD ENGINEERING AT 791-5550 TO DISCUSS CHANGES IN GRADING DESIGN. d) IF GRADING CONSTRUCTION IS EXPECTED TO LAST LONGER THAN THE EXPIRATION DATE OF THE GRADING PERMIT, CONTACT DSD TO RENEW/EXTEND THE GRADING PERMIT. IF FINAL GRADING INSPECTION HAS NOT BEEN COMPLETED BEFORE THE GRADING PERMIT EXPIRES, AND THE PERMIT HAS NOT BEEN RENEWED, ADDITIONAL FEES AND REVIEWS MAY BE REQUIRED. e) SEPARATE BUILDING PERMIT APPLICATIONS ARE REQUIRED FOR ANY WALLS. f) THE PERMITEE SHALL NOTIFY THE DSD WHEN THE GRADING OPERATION IS READY FOR FINAL GRADING INSPECTION. FINAL GRADING APPROVAL SHALL NOT BE GIVEN UNTIL ALL WORK, INCLUDING INSTALLATION OF ANY DRAINAGE IMPROVEMENTS AND THEIR PERMANENT PROTECTIVE DEVICES, AND ALL EROSION CONTROL MEASURES HAVE BEEN COMPLETED IN ACCORDANCE WITH THE APPROVED GRADING PLAN AND GRADING PERMIT, AND ALL CONDITIONS OF PERMIT ARE COMPLETED. g) THERE SHALL BE NO DISTURBANCE OUTSIDE OF THE DISTURBANCE/GRADING LIMITS AND NO DISTURBANCE OF THE WASH ORDINANCE AREA AS SHOWN ON THE APPROVED PLAN. 2) On sheet 1, provide delineation of the WASH Ordinance limits of disturbance (similar to sheet N-1) to ensure that there is no encroachment of the WASH Ordinance area. All improvements and construction disturbance including rear yard grading shall be outside of the WASH Ordinance protected area that is not to be disturbed. 3) Resubmit 4 copies of the site/grading plan for resubmittal. I can be reached at 791-5550, ext.2204 if you have questions. Elizabeth Eberbach, PE Civil Engineer Engineering Division Development Services Department |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 05/10/2007 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
| 05/10/2007 | SUE REEVES | REJECT SHELF | Completed |