Permit Review Detail
Review Status: Completed
Review Details: GRADING
Permit Number - T07BU00256
Review Name: GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/08/2007 | STEVE SHIELDS | ZONING | REVIEW | Denied | DSD TRANSMITTAL FROM: Steve Shields Lead Planner PROJECT: FARMER JOHN SELF STORAGE T07BU00256 Grading Plan (1st Review) TRANSMITTAL DATE: February 8, 2007 1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed. 2. Zoning could not verify that the grading plan was in compliance with the approved site plan. Please submit two copies of the approved and stamped site, landscape, and NPPO plans with the next grading plan submittal. 3. Zoning will re-review the grading plan on the next submittal to insure compliance with the approved and stamped site plan. Additional comments may be forthcoming. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 791-5608 ext. 1180. C:\planning\grading\t07bu00256 RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Approved site plans and additional requested documents |
| 02/16/2007 | ANDREW CONNOR | NPPO | REVIEW | Denied | Site plan approval is necessary to continue review. |
| 03/09/2007 | SUZANNE BOHNET | ENGINEERING | REVIEW | Denied | DATE: March 15, 2007 FROM: Suzanne Bohnet, CFM Engineering Division SUBJECT: 1102 W. Grant Rd. Farmer John Self-Storage Site Plan T06CM05073 (Second Review) RESUBMITTAL REQUIRED: Site Plan, Grading Plan and Drainage Report. The Site Plan, Grading Plan and Drainage Report cannot be approved as submitted. Please include a response letter to the comments below along with the corrected copies of the Site Plan and Grading Plan with your next submittal. In addition, provide two copies of the Drainage Report and Geotechnical Engineering Report with the next submittal, 4 copies of the Grading Plan and 3 copies of the Stormwater Pollution Prevention Plan. Site Plan: 1. Confirm that truncated domes are to be installed for the handicapped parking spaces located on the east side of the existing building. From the Site Plan, it appears that truncated domes are shown on the side ramps but not at the interface of the striped area in the parking lot and the flush sidewalk. Grading Plan: 1. Provide the water surface elevation of the three retention/detention basins in order to verify the finished floor elevation of adjacent buildings has the required one-foot freeboard. 2. Add a note stating: "All landscape areas are to be depressed 6" for water-harvesting purposes". 3. Add a note regarding basin inspection and maintenance per the Standards Manual for Drainage Design and Floodplain Management (SMDDFM) 14.3. 4. Add a note referencing the Geotechnical Engineering Report performed by LMT Engineering Inc. agreeing to abide by the recommendations and observations for grading activities. 5. Provide an access ramp to the large northwest retention/detention basin for maintenance purposes, the slope of which is not exceed 15% (SMDDFM 14.3.4). 6. Provide labels on the existing contour and the contour interval next to the north arrow and scale. Drainage Report: 1. Provide a detailed Basin Maintenance Checklist and Schedule in the Drainage Report (SMDDFM 2.3.1.2.E.1). Stormwater Pollution Prevention Plan: 1. The Stormwater Pollution Prevention Plan submitted is conditionally approved. Provide a copy of the Notice of Intent prior to Grading Permit issuance. Please do not hesitate to contact me with any questions. Thank you, Suzanne Bohnet, CFM Engineering Associate (520) 791-5550 x1188 office Suzanne.Bohnet@tucsonaz.gov |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/23/2007 | FSANCHE1 | OUT TO CUSTOMER | Completed |
| 03/23/2007 | SUE REEVES | REJECT SHELF | Completed |