Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL-BLDG/FIRE/ZONING/ENG
Permit Number - T07BU00130
Review Name: COMMERCIAL-BLDG/FIRE/ZONING/ENG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/20/2007 | DAVE MANN | FIRE | REVIEW | Approved | |
| 04/11/2007 | WILDAN | BUILDING-COMMERCIAL | REVIEW | Denied | April 11, 2007 City of Tucson Development Services P.O. Box 27210 Tucson, AZ 85726 RE: St. Ambrose Parish Porch Remodel CITY OF TUCSON LOG NO. T07BU00130 WILLDAN PROJECT NO. 13881-7038 – 1ST REVIEW The initial review for the above project has been completed. This letter contains comments which need to be addressed by written responses to each which indicate any actions taken. In order to facilitate a shorter second review, all corrections and revisions must be made on the original plans and two complete new sets of prints, along with one complete redlined set, must be returned to our office. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets, and that all changes have been highlighted with appropriate revision numbers, revision dates, and “cloud bubbles.” Pen or pencil corrections on final prints are not acceptable. This project has been reviewed for conformance with the 2003 IBC, 1997 UAC, 2003 IMC, 2003 IECC, 2002 NEC with local modifications, and the 2003 UPC. Any revisions to this plan will require an additional review and approval by Willdan. Should you have questions regarding the comments herein, please contact your plans examiner Chris Kiel. Occupancy Occup. Load Construction Area S.F. Sprinklered Alarms R-3 N/A V-B 367* No No * Porch area only Special Inspection is required for the following items: N/A The following items are acceptable for deferred submittals: N/A GENERAL COMMENTS: General Please have the engineer of record seal the plans associated with his design in accordance with the requirements of the Arizona State Board of Technical Registration. ARCHITECTURAL COMMENTS: General Please specify the roof pitch per section 106.1.1 of the 2003 IRC. STRUCTURAL COMMENTS: General Please provide verification that the 8x8 beams can support the applied loads per section 106.1.1 of the 2003 IRC. Please provide verification that the existing window headers/lintels can support the applied loads per section 106.1.1 of the 2003 IRC. Please specify the lumber grade and species on the plans per section 106.1.1 of the 2003 IRC. PLUMBING COMMENTS: Reviewed and accepted. MECHANICAL COMMENTS: Reviewed and accepted. ELECTRICAL COMMENTS: Reviewed and accepted. ENERGY CODE COMMENTS: Reviewed and accepted. ACCESSIBILITY COMMENTS: Reviewed and accepted. Sincerely, WILLDAN Chris Kiel, C.B.O., M.C.P. Building Official CEK/tb |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/24/2007 | SUE REEVES | OUT TO CUSTOMER | Completed |
| 04/24/2007 | SUE REEVES | REJECT SHELF | Completed |