Permit Number: T06SA00297
Parcel: 13609007F

Review Status: Completed

Review Details: RESUBMITTAL - OVERLAY ZONE REVIEW

Permit Number - T06SA00297
Review Name: RESUBMITTAL - OVERLAY ZONE REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/18/2007 PAUL MACHADO ENGINEERING REVIEW Approved
07/05/2007 JOE LINVILLE LANDSCAPE REVIEW Approv-Cond The Landscape Section recommend approval of the applications subject to compliance with the following:

1) A NPP plan is required for the offsite sewer proposed on the tentative plat prior to approval. LUC 3.8.3.1
Revise the plans to include provisions for irrigation and maintenance for plant establishment.

2) LUC 3.8.6.7.B, Fencing shall remain in place for the duration of construction activities. Revise the Native Plant Preservation Plan fencing notes to include this imporatnt element of NPPO and ERZ compliance. LUC 2.8.6.6.C

3) Revise the calculation for the NUOS area on NPPP-1 and ERZ-NPPO to correspond. The values differ on the current
plans.

4) Revise the plat and associated plans to include include landscape easements for mitigation areas proposed on individual lots. Clarify maintenance plans and responsibilities.
Include provisions for maintenance of the mitigation areas in the CC&R's.
07/10/2007 KAROL ARAGONEZ ZONING REVIEW Approved CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Karol Aragonez
Planner

PROJECT: T06SA00297
Venado Vista
Overlay Zone Review (ERZ)

TRANSMITTAL DATE: July 10, 2007

DUE DATE: July 10, 2007

COMMENTS:

The Zoning Review Section verifies that the overlay zone review of the tentative plat meets the requirements of the Land Use Code. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the corrected tentative plat to verify that those changes do not affect any zoning requirements.



If you have any questions about this transmittal, please call Karol Aragonez, (520) 791-5550, ext. 1197.

KAA S:\zoning review\karol\planning\cdrc\tentativeplat\T06SA00297ozr.doc
07/16/2007 PATRICIA GEHLEN ZONING-DECISION LETTER WRITE DECISION LETTER Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

July 16, 2007

Holly Barnes
Novak Environmental, Inc.
4574 North 1st Avenue, Suite 100
Tucson, Arizona 85718

Subject: T06SA00297 Environmental Resource Overlay Zone for Venada Vista Subdivision (S06-203)

Dear Holly:

Your submittal of June 12, 2007 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter for each agency explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

2 Copies Revised Overlay zone submittal package as detailed in the on line comments (Landscape, DSD).


Final approval may not be given until staff has approved the overlay submittal and the proposal is approved by SAC.




Should you have any questions, please call me at 791-5608, ext. 1179.

Sincerely,


Patricia Y. Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/


Via fax: 322-6956