Permit Review Detail
Review Status: Completed
Review Details: LUCAPPS - OVERLAY ZONE REV
Permit Number - T06SA00297
Review Name: LUCAPPS - OVERLAY ZONE REV
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
03/13/2007 | KAROL ARAGONEZ | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Karol Aragonez Planner PROJECT: T06SA00297 Venado Vista Overlay Zone Review (ERZ) TRANSMITTAL DATE: March 13, 2007 DUE DATE: March 27, 2007 COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. ERZ LUC 2.8.6 Comments: 1. This project requires an Environmental Resource Report and a mitigation plan to be reviewed by Stormwater Advisory Committee (SAC), who then makes recommendations to the DSD Director. 2. The Overlay Zone case number, T06SA00297, must be noted in the lower right corner of each sheet of the tentative plat, landscape, and NPPO plans. All required elements of the ERZ as shown on the approved Overlay Zone plan must be added to the tentative plat, along with date of approval and any conditions placed on that approval. The tentative plat may not be approved prior to Overlay Zone application approval. (LUC 2.8.2) (LUC 2.8.1) (D.S. 2-12) (D.S. 9-04) 3. Please add the following note to the tentative plat "All utilities will be located underground and will be placed along the roadway improvements of within approved easements". 4. Please add the following note to the tentative plat "No grubbing, grading, or construction will occur until those areas designated as NUOS are temporarily fenced. All temporary fencing will be field inspected before any construction onsite begins. Fencing will be removed only on completion of construction". 5. Please add the following note to the tentative plat "Neither fences or walls will be allowed which impede wildlife movement through designated critical riparian areas except for temporary fencing". If you have any questions about this transmittal, please call Karol Aragonez, (520) 791-5550, ext. 1197. KAA S:\zoning review\karol\planning\cdrc\tentativeplat\T06SA00297oz.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised tentative plat and additional requested documents. |
03/26/2007 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | The Landscape Section does not recommend approval of the application at this time. The ERR and associated plans should address the following code requirements. Utility encroachments into critical riparian habitat areas will be limited and approved only if there are no other alternatives in the design of the project. Explain why the proposed encroachment of the sewer line is the only approach available and why there are no viable alternatives. LUC 2.8.6.6.A.1 The distubance proposed to the Coronado Ridge Wash appears to be well over 100 feet wide at the southern portion of the site. The mitigation plan is required to lessen the impacts of the development on the critical riparian habitat areas per LUC 2.8.6.5.D.3 and provide for one hundred (100) percent restoration of the critical riparian habitat area disturbed during construction. Revise the plans as necessary to minimize the impact if possible and to revegetate disturbed areas. |
05/07/2007 | PAUL MACHADO | ENGINEERING | REVIEW | Denied | To: Patricia Gehlen DATE: May 7, 2007 CDRC/Zoning Manager FROM: Paul Machado Engineering Division SUBJECT: 1470 S. Melpomene Way ERZ Overlay T06SA00297 (First Review) T14S, R15E, Section 24 RESUBMITTAL REQUIRED: Overlay Zone Review ERZ Overlay: 1. Please include a response letter to the comments along with the corrected copies of the Overlay Review. 2. This project requires an Environmental Resource Report and a mitigation plan to be reviewed by Stormwater Advisory Committee (SAC), who then makes recommendations to the DSD Director. 3. The Overlay Zone case number, T06SA00297, must be noted in the lower right corner of each sheet of the tentative plat, landscape, and NPPO plans. All required elements of the ERZ as shown on the approved Overlay Zone plan must be added to the tentative plat, along with date of approval and any conditions placed on that approval. The tentative plat may not be approved prior to Overlay Zone application approval. (LUC 2.8.2) (LUC 2.8.1) (D.S. 2-12) (D.S. 9-04). 4. Please add the following note to the tentative plat "All utilities will be located underground and will be placed along the roadway improvements of within approved easements". 5. Please add the following note to the tentative plat "No grubbing, grading, or construction will occur until those areas designated as NUOS are temporarily fenced. All temporary fencing will be field inspected before any construction onsite begins. Fencing will be removed only on completion of construction". If you have any questions, I can be reached at 837-4932 or Paul.Machado@ci.tucsonaz.govs Paul P. Machado Senior Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4932 office (520) 879-8010 fax C:/1470 S. Melpomene Way Overlay |
05/08/2007 | PATRICIA GEHLEN | ZONING-DECISION LETTER | WRITE DECISION LETTER | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES May 8, 2007 Holly Barnes Novak Environmental, Inc. 4574 North 1st Avenue, Suite 100 Tucson, Arizona 85718 Subject: T06SA00297 Environmental Resource Overlay Zone for Venada Vista Subdivision (S06-203) Dear Mirela: Your submittal of February 27, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter for each agency explaining how each outstanding requirement has been addressed: ALL BLUELINES MUST BE FOLDED 4 Copies Revised Overlay zone submittal package as detailed in the on line comments (Landscape, Zoning, Engineering, DSD). The public comment period will be opened during the week of May 7, 2007. Should you have any questions, please call me at 791-5608, ext. 1179. Sincerely, Patricia Y. Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 322-6956 |