Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T06SA00279
Parcel: 13303283E

Address: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - OVERLAY ZONE REVIEW

Permit Number - T06SA00279
Review Name: RESUBMITTAL - OVERLAY ZONE REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/11/2007 PAUL MACHADO ENGINEERING REVIEW Denied To: Patricia Gehlen DATE: June 11, 2007
CDRC/Zoning Manager

SUBJECT: La Mariposa Subdivision.
Scenic Overlay T06SA00279 (First Review)
T14S, R15E, Section 02

RESUBMITTAL REQUIRED: Overlay Zone Review.

ERZ Overlay:

1. Please include a response letter to the comments along with the corrected copies of the Overlay Review.
2. It appears the floodplain boundaries have been changed and differ greatly from the previous submittal. The floodplain limits are not from any map DSD is familiar with. Explain how the flood plain limits were derived and it's source.
3. The Overlay Zone case number, T06SA00279, must be noted in the lower right corner of each sheet of the tentative plat, landscape, and NPPO plans. All required elements of the SCZ as shown on the approved Overlay Zone plan must be added to the tentative plat, along with date of approval and any conditions placed on that approval. The tentative plat may not be approved prior to Overlay Zone application approval. (LUC 2.8.2) (LUC 2.8.1) (D.S. 2-12) (D.S. 9-04).


If you have any questions, I can be reached at 837-4932 or Paul.Machado@ci.tucsonaz.govs
Paul P. Machado
Senior Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 837-4932 office
(520) 879-8010 fax
C:/ La Mariposa overlay zone
05/21/2007 JOE LINVILLE LANDSCAPE REVIEW Approv-Cond 1) Verification and approval of the floodplain limits is required for ERZ compliance.
06/01/2007 KAROL ARAGONEZ ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office

FROM: Karol Aragonez
Planner

PROJECT: T06SA00279
La Mariposa Subdivision
Overlay Zone review

TRANSMITTAL DATE: May 25, 2007

DUE DATE: June 4, 2007

COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

A copy of the tentative plat was not submitted as part of the overlay zone submittal. The following items were reviewed as part of S06-235 tentative plat review. The following corrections are to be made on the tentative plat.

1. Please clarify on the tentative plat that the thirty (30) foot undisturbed natural landscape buffer extends the entire length of the proposed frontage along Houghton Road. It appears that it ends at the middle of Lot 1.

2. Please correct SCZ note 1 replacing the subdivision case number S06-235 with the overlay case number T06SA00279.

3. Please revise SCZ note 7 to read - Building or structure surfaces, which are visable from Houghton Road will have "earth tone" colors.

4. Once Engineering has completed their review of the tentative plat, landscape plan, and ERR and have approved that submittal, Zoning Review will then approve ERZ.

If you have any questions about this transmittal, please call Karol Aragonez, (520) 791-5550, ext. 74960.

KAA S:\zoning review\karol\planning\cdrc\overlay zone review\T06SA00279ozr.doc


RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised tentative plat and additional requested documents.
06/06/2007 FRODRIG2 CONSERVATION & SUSTAINABLE DEVELOPMENT OCSD Denied >>> Frank Sousa 06/06/2007 9:41 AM >>>
This comment applies to both resubmittals.

The depicted 100-year floodplain boundary could not be verified with data available from either the Pima County Regional Flood Control District (PCRFCD) or from Development Services Department staff. The revised rezoning report appears to have the used the appropriate floodplain delineation on the revised development plan, though that revised plan does not appear to match the current resubmittal. Please correct the floodplain delineation to match the PCRFCD proposed floodplain delineation and correct all associated documents (ERR, tentative plat, etc) accordingly.

Francis X. Sousa
Lead Hydrologist
Department of Transportation
Engineering Division
Stormwater Section
City of Tucson
520-837-6581, voice
520-791-4373, fax
frank.sousa@tucsonaz.gov
06/11/2007 PATRICIA GEHLEN ZONING-DECISION LETTER WRITE DECISION LETTER Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

June 11, 2007

Jessie Byrd
Novak Environmental, Inc.
4574 North 1st Avenue, Suite 100
Tucson, Arizona 85718

Subject: T06SA00279 Scenic Corridor and Environmental Resource Overlay Zones for Wootton Property Tentative Plat (S06-235)

Dear Jessie:

Your submittal of May 4, 2007 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter for each agency explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

5 Copies Revised Overlay zone submittal package as detailed in the on line comments (Landscape, Zoning, Engineering, OCSD, DSD).









Should you have any questions, please call me at 791-5608, ext. 1179.

Sincerely,


Patricia Y. Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/


Via fax: 882-3006