Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - OVERLAY ZONE REVIEW
Permit Number - T06SA00248
Review Name: RESUBMITTAL - OVERLAY ZONE REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/18/2008 | DAVID RIVERA | ZONING | REVIEW | Approved | |
| 11/19/2008 | ELIZABETH EBERBACH | ENGINEERING | REVIEW | Approved | DATE: November 19, 2008 SUBJECT: 3007 W Via De Suenos HDZ 4th Engineering Review REVIEWER: Elizabeth Eberbach ACTIVITY NUMBER: T07BU01547, T06SA00248, T06CM02975 SUMMARY: The revised residential overlay package with site/grading plans were received and reviewed by Engineering. The Overlay package was submitted and reviewed with the revised site/grading plans. Accuracy of data appears to be within a reasonable tolerance; ACS calculation for this parcel is accepted. Engineering recommends approval of the Overlay review, and recommends approval of the site / grading plan reviews for grading permit issuance. The following conditions apply to the grading permit. GRADING PERMIT CONDITIONS: The following 11 conditions apply to grading permit T07BU01547: 1) Call for Pre-construction meeting. For a DSD Engineering Inspection, call IVR (740-6970), or schedule with a Customer Service Representative at the Development Services Department, or contact DSD Engineering at 791-5550 extension 2101, or schedule inspections online at: http://www.ci.tucson.az.us/dsd/Online_Services/Online_Permits/online_permits.html 2) A copy of the Grading Plan and Grading Permit shall be kept at the site at all times, until final grading approval. 3) Any revision to the Grading Plan MAY require a re-submittal of a revised grading plan for review. Contact DSD Engineering at 791-5550 to discuss changes in grading design. 4) At intermediate inspection stage, call for inspections of rear cut slope and interceptor swale construction. 5) Besides pre-con, intermediate, and final inspections, call DSD Engineering Inspector for interceptor swale construction inspections. 6) If grading construction is expected to last longer than the expiration date of the grading permit, contact DSD to renew/extend the Grading Permit. If Final Grading Inspection has not been completed before the Grading Permit expires, and the permit has not been renewed, additional fees and reviews may be required. 7) Erosion protection shall be provided in the form of handplaced rip rap with filter fabric, or grouted handplaced rip rap at ends of drainageways or channels prior to outflowing onto natural desert areas or access easement to assure permanent erosion protection. 8) There shall be no disturbance outside of the approved disturbance/grading limits as shown on the approved plan. If disturbance occurs outside of the grading limits (except for installation of septic system emitter field) the site will be subject to Stop Work Order and/or resubmittal review of the overlay, site, and grading plans, as well as additional fees. 9) Area next to south side of building near base of cut slope shall provide positive drainage from structure. Consider impervious material at this location. 10) Separate building permit applications / reviews are required for any walls. 11) The permitee shall notify the DSD when the grading operation is ready for final grading inspection. Final grading approval shall not be given until all work, including installation of all drainage improvements and their permanent protective devices, and all erosion control measures have been completed in accordance with the approved grading plan and grading permit, and all conditions of permit are completed. If you have questions, you may call me at 837-4934. Elizabeth Eberbach, PE Civil Engineer Engineering Division Development Services Department |
| 12/01/2008 | PATRICIA GEHLEN | ZONING-DECISION LETTER | WRITE DECISION LETTER | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES November 28, 2008 Rodolfo B. Garcia 5518 South Bryant Stravenue Tucson, Arizona 85706 Subject: T06SA00248 Hillside Development Zone for 3007 West Via De Suenos (T06CM02975) Dear Rodolfo: Your submittal of November 17, 2008 for the above project has been reviewed by the Community Design Review Committee and CONDITIONALLY APPROVED. The conditions of approval are as follows: 1) closing of the public comment period and 2) approval by the DSD Director. Please add a general note to the plans which state the case number, date of approval, type of overlay and conditions imposed, if any. The case number must be added to each sheet of the plan set in the lower right hand corner. Should you have any questions, please call me at 837-4919. Sincerely, Patricia Y. Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: No Fax -letter has to be mailed. |