Permit Number: T06SA00237
Parcel: 30506003V

Review Status: Completed

Review Details: LUCAPPS - OVERLAY ZONE REV

Permit Number - T06SA00237
Review Name: LUCAPPS - OVERLAY ZONE REV
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/23/2006 JOE LINVILLE LANDSCAPE REVIEW Denied The Landscape Section does not recommend approval.

1) Submit the information required per TCC sec. 29-15 including the specific requirements for the hydrology/hydraulic study, and a detailed Plant/Habitat Inventory for all points where development impacts the study area of regulated washes on the site.

2) Submit detailed mitigation plans for any resource area development, including a preservation/revegetation plan.

Refer to

http://dot.tucsonaz.gov/stormwater/downloads/washguidetoM_C.pdf

for guidelines on plan preparation.

3) Revise page the last paragraph on page 6 of the
Hydrology and Hydraulics Design Report. The regulated washes on the site are subject to TCC sec 29, Article VIII. & the existing 10 year flood limits should not be treated as the resource area, as the resource area may encompass the entire study area on this site.
10/25/2006 HEATHER THRALL ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office

FROM: Heather Thrall, Senior Planner

PROJECT: T06SA00237
Rincon Knolls, S06-125, Residential Cluster Project Subdivision
Special Overlay Zone Application, Hillside Development Zone Review

TRANSMITTAL DATE: October 25, 2006

DUE DATE: October 24, 2006

COMMENTS:
1. This submittal was reviewed for compliance with the Land Use Code, specifically the Hillside Development Overlay Zone, Section 2.8.1. Zoning review staff defers jurisdiction of WASH Overlay application review to the Engineering division of Development Services.

2. Please place the special application overlay case number T06SA00237 near the title block of all pages of the application and the plat, specifying the overlay application is for WASH Overlay and Hillside Development Overlay Zone.

3. Per LUC 2.8.1.3.A, please identify any protected peak and ridge areas and show a 300' setback line from peak in all directions.

4. Per LUC 2.8.1.6.C, Provide Average Cross Slope Analysis to engineering division. See Engineering comments for further review.

5. Per LUC 2.8.1.8.A. provide a note stating that the maximum building height is 24' for residential development in the HDZ. (Height, per diagram provided, is measured from design grade to the midpoint of a gable roof or a flat roof. See diagram LUC 2.8.1.8)

6. Per LUC 2.8.1.8.C, provide note with regards to colors: "all exposed exterior walls and roofs of structures, retaining walls, and accessory structures shall be earth tone in color."

7. The HDZ submittal is to be integrated, information wise, in the actual tentative plat.

8. Please note, depending upon responses provided, further review comments may be forthcoming. Should you have any questions on this review, please contact me at Heather.Thrall@tucsonaz.gov or at 520-791-4541x1156.

C:\planning\cdrc\developmentplan\T06SA00237 rincon knolls hillside.doc
RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised tentative plat.
11/17/2006 LOREN MAKUS ENGINEERING REVIEW Approved DATE: November 16, 2006
To: Patricia Gehlen
CDRC/Zoning Manager
FROM: Loren Makus, EIT
Engineering Division

SUBJECT: Rincon Knolls
T06SA00237 WASH and HDZ Review (First Review)
T16S, R16E, Section 34
RESUBMITTAL REQUIRED:None

The WASH report and associated materials have been reviewed by the Engineering Division and we recommend approval. The engineering review and approval applies to the delineations and hydrology.

If you have any questions, I can be reached at 791-5550 x1161 or loren.makus@tucsonaz.gov.

Loren Makus, EIT
Senior Engineering Associate
11/22/2006 PATRICIA GEHLEN ZONING-DECISION LETTER WRITE DECISION LETTER Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

November 22, 2006

Merwin Yellowhair, P.E.
America Built Development
5255 East Williams Circle Suite 6000W
Tucson, Arizona 85711

Subject: T06SA00237 WASH and Hillside Development Zone Overlays for Rincon Knolls Subdivision (S06-125)

Dear Merwin:

Your submittal of September 28, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter for each agency explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

3 Copies Revised Overlay zone submittal package as detailed in the on line comments (Zoning, Landscape, DSD).


The public comment period will be opened within the next two weeks.





Should you have any questions, please call me at 791-5608, ext. 1179.

Sincerely,


Patricia Y. Gehlen
CDRC Manager