Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Number: T06SA00232
Parcel: 136141400

Review Status: Completed

Review Details: LUCAPPS - OVERLAY ZONE REV

Permit Number - T06SA00232
Review Name: LUCAPPS - OVERLAY ZONE REV
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/09/2006 JOE LINVILLE LANDSCAPE REVIEW Approv-Cond The Landscape Section recommends approval of the application based on the approved tentative plat and the WASH review by STAC and subsequent variance approval by Mayor and Council.

However, the grading plans included with the application do not match the grading limits shown on the approved wash plans, native plant preservation plans and landscape plans. The grading plans require revision.
10/10/2006 LAITH ALSHAMI ENGINEERING REVIEW Denied Laith Alshami, Engineering and Floodplain Review, 10/10/2006

TO: Patricia Gehlen FROM: Laith Alshami, P.E.
CDRC Engineering

SUBJECT: Lakeside Ridge
T06SA00232, Ref. (S03-001), T14S, R15E, SECTION 28

RECEIVED: WASH Ordinance required Mitigation Report/Plan for Atterbury Wash on September 15, 2006

The subject project has been reviewed. The Mitigation Report shall be approved once the following comments have been satisfactorily addressed:

1. Provide documentation, which verifies that the proposed crossing is acceptable by the Army Corp of Engineers (404 Permit).
2. Submit an ADEQ approved copy of the SWPPP that addresses the proposed crossing.


RESUBMITTAL REQUIRED: Documentation required above
10/12/2006 DAVID RIVERA ZONING REVIEW Passed CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office
FROM: David Rivera
Principal Planner

PROJECT: T06SA00232
Lakeside Ridge
Overlay Zone Review

TRANSMITTAL DATE: October 12, 2006

DUE DATE: October 13, 2006

COMMENTS: Zoning does not have adverse comments related to the WASH overlay application. Zoning does however require approval of the WASH overlay application prior to conditional or final approval of the tentative plat.
10/20/2006 PATRICIA GEHLEN ZONING-DECISION LETTER WRITE DECISION LETTER Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES


October 20, 2006

Jeff Stanley
Stanley Engineering and Drainage
PO Box 1888
Tucson, Arizona 85702

Subject: T06SA00232 WASH Overlay Zones for Lakeside Ridge (S03-001)

Dear Jeff:

The above referenced plan has been CONDITIONALLY APPROVED by the Community Design Review Committee, subject to the on line comments. Compliance with the on-line comments will be verified through revisions to the grading and SWPPP plans.










Should you have any questions, please call me at 791-5608, ext. 1179.

Sincerely,


Patricia Y. Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/


Via fax: 792-0318