The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Permit Number: T06SA00220
Parcel: 14029050A

Review Status: Completed

Review Details: RESUBMITTAL - OVERLAY ZONE REVIEW

Permit Number - T06SA00220
Review Name: RESUBMITTAL - OVERLAY ZONE REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/13/2007 JASON GREEN ENGINEERING REVIEW Approv-Cond DATE: September 12, 2007
SUBJECT: Hemisphere Corporate Center W.A.S.H. Overlay Submittal- 3rd Engineering Review
TO: Patricia Gehlen; CDRC Manager
LOCATION: 6300 S Palo Verde Road, T15S R14 E Sec09 Ward 5
REVIEWER: Jason Green, CFM
ACTIVITY: T06SA00220

PROJECT SAC SUMMARY: Engineering Division of Development Services Department has received the revised W.A.S.H./Environmental Resource Report for Rodeo Wash at Hemisphere Corporate Center (Rick Engineering Company, 31AUG07). The Hemisphere Corporate Center project proposes encroachment into the Rodeo W.A.S.H. Ordinance Wash. The existing Rodeo Wash is a constructed channel, approximately 8 feet deep and top width 80 feet, with earthen bottom and 3.5:1(H: V) side slopes. Proposed encroachment includes parking spaces associated with the vehicular use area and refuse containers that encroaches 33.5-feet into the 50-foot study area along the southwest portion of the project. The project proposes to sheet flow the stormwater runoff from the vehicular use area into a 16.5-foot wide enhanced landscape area within the W.A.S.H. Study Area. The encroachment is a continuous design associated with the development to the north (Lot 41) and will keep the same linear design approach that will mitigate more plants along the bank of the Rodeo Wash.

Engineering recommends scheduling a SAC meeting for the associated encroachment into the Rodeo W.A.S.H. Study Area per the design shown on the submitted report. Although the southern portion of the property has already been mass graded in the past under the Phases development for this project the encroachment of the parking spaces is accepted due to the continuous design of the adjacent development

ENVIRONEMNTAL RESOURCE COMMENTS:
DS Sec.1-01.4.7: It is acknowledge that a Development Standard Modification Request (DSMR) has been requested for the proposed disturbance of the Protected Riparian Area (PRA) located in the northeast corner of the subject site (outside of the W.A.S.H Study Area). The Development Plan can not be approved prior to DSMR approval. All conditions of the DSMR must be reflected on a revised Development Plan and the revised drainage report.

Any redesign to the project that requires additional encroachment into the W.A.S.H. Study Area will require a new review of the W.A.S.H. report and will require a new SAC meeting.

GENERAL COMMENTS:

Provide an approved DSMR that addresses the comments provided above.

Further comments may be generated upon resubmittal of the DSMR.

If you have questions or would like to set up a meeting, call me 837-4929.



Jason Green, CFM
Senior Engineer Associate
Engineering Division
Development Services
09/25/2007 JOE LINVILLE LANDSCAPE REVIEW Approved
09/26/2007 PATRICIA GEHLEN ZONING-DECISION LETTER WRITE DECISION LETTER Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

September 26, 2007

Tri Miller
Rick Engineering Company
1745 East River Road, Suite 101
Tucson, Arizona 85701

Subject: T06SA00220 WASH Overlay Zone for 3550 East Hemisphere Loop (D06-0024)

Dear Tri:

Your submittal of August 3, 2007 for the above project has been reviewed by the Community Design Review Committee and CONDITIONALLY APPROVED. The conditions of approval are as follows: 1) Review by Stormwater Advisory Committee (SAC), 2) closure of the public comment period, 3) approval by the DSD Director, and 4) the comments below the Engineering comments are addressed on the development plan.

The overlay case number must be added to each sheet of the development, landscape and NPPO plans in the bottom right corner, near the title block. In addition, a general note must be added to the development plan that states the case number, date of approval, type of overlay, and conditions imposed.







Should you have any questions, please call me at 837-4919.

Sincerely,


Patricia Y. Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/


Via fax: 322-6956