Permit Number: T06SA00188
Parcel: 11931018A

Review Status: Completed

Review Details: RESUBMITTAL - OVERLAY ZONE REVIEW

Permit Number - T06SA00188
Review Name: RESUBMITTAL - OVERLAY ZONE REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/04/2007 ANDREW CONNOR LANDSCAPE REVIEW Denied The Landscape Section does not recommend approval of the application. The native plant preservation plan submitted was reviewed only as it relates to HDZ compliance. Additional comments may apply with subsequent reviews.

1. The natural area percentage must also be delineated in a surveyable manner and designated by legal description on a document recorded with the Pima County Recorder.

2. To protect the natural areas, a covenant must be provided with record interest in the natural area in favor of the City of Tucson per LUC 2.8.1.7.D. Submit the required covenant and legal description for review.

3. Prior to approval verify that all Engineering comments, concerns and appropriate revisions have been addressed.
01/08/2007 STEVE SHIELDS ZONING REVIEW Approv-Cond DSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: 3163 W. Mockingbird Lane
T06SA00188
Overlay Zone Application - Hillside Development & Environmental Resources

TRANSMITTAL DATE: January 8, 2007

COMMENTS:
1. The Zoning Review Section approves the Hillside Development & Environmental Overlay Zone Application. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised final plat to verify that those changes do not affect any zoning requirements.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 791-5608 ext. 1180.

C:\planning\hillside\T06SA00188-2nd.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents
02/08/2007 ELIZABETH EBERBACH ENGINEERING REVIEW Approv-Cond SUBJECT: 3163 W Mockingbird Lane HDZ Engineering Review
REVIEWER: Elizabeth Eberbach
ACTIVITY NUMBER: T06SA00188

SUMMARY: The revised Overlay package was submitted for review. Engineering recommends conditional approval of the overlay plan.

OVERLAY CONDITION OF APPROVAL:
1) Grading Plan review approval is necessary for construction activity at the site.
2) DS Sec.2-12.2.3: In order to determine mitigation due to recent grading activities, address the following for current disturbed area:
a) Provide a survey completed by a registered surveyor that delineates and labels the limits and square footage of the total current disturbed area;
b) Until the Stop Work Order is lifted by the City of Tucson, only the following activities are allowed:
i) Shoring or covering of any excavated areas for safety reasons
ii) Placement of interim erosion / sediment control measures, including immediate placement and installation of straw bale or similar device for stormwater control.
iii) Surveyor work for determining disturbance limits.

For questions or to set up a meeting, call me at 791-5550, extension 2204.

Elizabeth Eberbach, PE
Civil Engineer
Engineering Division
Development Services
02/09/2007 PATRICIA GEHLEN ZONING-DECISION LETTER WRITE DECISION LETTER Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

February 9, 2007

Eduardo Ornelas
Arquitecto E.J. Ornelas
100 North Stone Ave., Suite 1002
Tucson, Arizona 85701

Subject: T06SA00188 Hillside Development and Environmental Resource Overlay Zones for 3163 West Mockingbird Lane (T06CM01370)

Dear Eduardo:

Your submittal of December 13, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter for each agency explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

3 Copies Revised Overlay zone submittal package as detailed in the on line comments (Engineering, Landscape, DSD).




Should you have any questions, please call me at 791-5608, ext. 1179.

Sincerely,


Patricia Y. Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/


Via fax: No fax number provided on application
02/09/2007 PATRICIA GEHLEN ZONING-DECISION LETTER WRITE DECISION LETTER Denied March 26, 2010


Eduardo Ornelas
Arquitecto E.J. Ornelas
100 North Stone Ave Suite 1002
Tucson, Arizona 85701

SUBJECT: CLOSURE OF CDRC FILES


Hillside and Environmental Resource Overlay Reviews

Maximum Review Period
The subdivider has one (1) year from the date of plan submittal to obtain approval of the plans. Failure to obtain approval means the review period has expired

Case # Case Name DSD Transmittal Date

T06SA00188 3163 West Mockingbird Lane July 14, 2006



Please note that this case has been closed and that, in order to continue review of the project, new development plan/tentative plat applications are required which comply with regulations in effect at the time of the new submittals.


Thank you for your assistance.

Sincerely,



Patricia Y. Gehlen
CDRC Manager


xc: CDRC file T06SA00188