Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - OVERLAY ZONE REVIEW
Permit Number - T06SA00107
Review Name: RESUBMITTAL - OVERLAY ZONE REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/14/2007 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 03/15/2007 | ANDREW CONNOR | LANDSCAPE | REVIEW | Denied | The Landscape Section does not recommend approval of the application. The native plant preservation plan submitted was reviewed only as it relates to HDZ compliance. Additional comments may apply with subsequent reviews. 1. Submittal of slope information is required to allow the Zoning Review Section at the Development Services Department (DSD) to review, comment upon, and make recommendations concerning the appropriate location of grading. 2. The following slope analysis information must be provided on the plan. For specific information on calculations of slope, refer to Development Standard 9-04.0. a. The average natural cross slope (ACS) analysis must be submitted with the plan and the ACS must be listed in the general notes on the plan. b. If the development criteria of Sec. 2.8.1.6 of the LUC require an analysis of sloped areas, those areas of fifteen (15) percent or greater slope must be shown on a topographic map. c. All protected peaks and ridges must be shown and labeled, and the three hundred (300) foot setback area must be delineated. 2. Average natural cross-slope (ACS) is calculated for the entire lot or parcel. Natural areas may be designated on the lot or parcel, in accordance with Sec. 2.8.1.7, to reduce the ACS percentage. Such designated natural areas will be excluded from the ACS calculation but will be included in the land area for the lot or parcel. Add the following notes to site plan (Including heading): CITY OF TUCSON DEVELOPMENT STANDARD NO. 9-04.0 HILLSIDE DEVELOPMENT SITE IMPROVEMENT Add the following notes to site plan (Including heading): A. Vegetation Retention. 1. Existing trees with four (4) inch or greater trunk diameter and cacti will be preserved in their original locations, except for building sites and access and utilities serving building sites. 2. When retention of the above trees and cacti in their original locations is not possible due to building site location, the trees and cacti will be salvaged and replanted in areas requiring re-vegetation, whenever possible. B. Re-vegetation. All cut or fill slopes, which are no steeper than three (3:1) and all utility trenches or septic leaching fields which are not located in parking or driveway areas will be re-vegetated in compliance with the following requirements. 1. All plants used in re-vegetation must be the same as the native vegetation on the site or any adjacent site prior to grading or clearing. 2. Re-vegetation will be accomplished with the following minimum requirements for plants. a. Native trees, a minimum of fifteen (15) gallon size with a minimum trunk diameter of two (2) inches measured at the soil level, or large specimen cactus will be placed at the same vegetation density found on the site prior to any clearing, grubbing, or grading. b. Seeds for trees, desert shrubs, and grasses will be planted with a density adequate to control erosion and may use one of the following methods of planting or any other method approved by the Zoning Review Section at DSD. 1) Raked into the soil with appropriate mulch materials; 2) Hydro-seeding; 3) Anchored mulches; or 4) Established on jute, rolled straw, or similar material. C. A temporary watering system must be installed until the re-vegetation materials is established. D. Fencing shall be required during construction per DS 2-06.8.0 Fig.1 for all undisturbed natural desert areas of Protected Native Plants and for individual Protected Native Plants to be preserved-in-place. The area to be fenced shall be beyond the "drip-line" of the vegetation by one-half (½) the distance of the "drip-line" radius. For Saguaros and cacti, the area to be fenced shall be equal to the distance of one-half (½) the height of the plant per DS 2-15.6.0 E. NPPO pre permit inspection is required prior to grading inspection can be scheduled by calling IVR system and entering inspection code 09015 or calling Landscape Field Representative directly @ 791-5550 EXT 1140 F. Grubbing, grading, and clearing are to occur only within the areas identified on the grading plan and staked on the site or lot. The limits should include all cut and fill areas, leach fields, septic tanks and future development areas identified G. The portions of the site or lot to be left ungraded are to remain undisturbed and are not to be used for stockpiling of materials or excess fill, construction vehicle access, storage of vehicles during construction, or similar uses. H. Development other than hiking trails will not be permitted within the legally described boundaries of the natural area. 3. Include the location, size, color, and textural treatment of all retaining walls, riprapped slopes, or other constructed means of slope stabilization must be shown on one (1) of the plans submitted. Vegetation retention and re-vegetation should be used in conjunction with riprapping. 4. Revise the site, grading, and NPPO plans to delineate the NUOS set-aside per LUC 3.8.6.7.D 5. The natural area percentage must also be delineated in a surveyable manner and designated by legal description on a document recorded with the Pima County Recorder. 6. To protect the natural areas, a covenant must be provided with record interest in the natural area in favor of the City of Tucson per LUC 2.8.1.7.D. Submit the required covenant and legal description for review. |
| 03/15/2007 | ANDREW CONNOR | LANDSCAPE | REVIEW | Denied | 1. The Landscape Section does not recommend approval of the application. The native plant preservation plan submitted was reviewed only as it relates to HDZ compliance. Additional comments may apply with subsequent reviews. 2. To protect the natural areas, a covenant must be provided with record interest in the natural area in favor of the City of Tucson per LUC 2.8.1.7.D. Submit the required covenant and legal description for review. |
| 03/22/2007 | ELIZABETH EBERBACH | ENGINEERING | REVIEW | Approved | SUBJECT: 3180 W Mockingbird Lane HDZ Engineering Resubmittal Review REVIEWER: Elizabeth Eberbach ACTIVITY NUMBER: T06SA00107 SUMMARY: The residential overlay documents were reviewed by Engineering with Stantec and owner at a meeting on 22MAR07. Engineering recommends approval of the HDZ Overlay package. One copy of the HDZ documents, including documentation of approval for the overlay will be needed for grading permit approval. For questions or to set up a meeting, call me at 791-5550, extension 2204. Elizabeth Eberbach, PE Civil Engineer Engineering Division Development Services |
| 03/29/2007 | PATRICIA GEHLEN | ZONING-DECISION LETTER | WRITE DECISION LETTER | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES March 29, 2007 Peter and Joan Bond, Equitable Owners BDC Development, Inc., Consultant 506 Midland Avenue Berwyn, PA 19312 Subject: T06SA00107 Hillside Development Overlay Zone for 3180 West Mockingbird Lane (No base plan submitted yet) Dear Eduardo: Your submittal of February 13, 2007 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter for each agency explaining how each outstanding requirement has been addressed: ALL BLUELINES MUST BE FOLDED 2 Copies Revised Overlay zone submittal package as detailed in the on line comments (Landscape, DSD). Should you have any questions, please call me at 791-5608, ext. 1179. Sincerely, Patricia Y. Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: (610) 648-0446 |