Plan Number: T06PI00039
Parcel: Unknown

Review Status: Completed

Review Details: PIA RESUBMITTAL

Plan Number - T06PI00039
Review Name: PIA RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/11/2006 TAMI HAUSER ENGINEERING REVIEW Needs Review
10/11/2006 TAMI HAUSER UTILITY CLEARANCES COT STREETS DIVISION Completed
10/11/2006 TAMI HAUSER UTILITY CLEARANCES COT WATER NEW DEVELOPMENT Completed
10/11/2006 TAMI HAUSER UTILITY CLEARANCES PC WASTEWATER MGMT Completed
10/11/2006 TAMI HAUSER UTILITY CLEARANCES QUEST COMMUNICATION Completed
10/11/2006 TAMI HAUSER UTILITY CLEARANCES TUCSON ELECTRIC POWER CO Completed
10/11/2006 TAMI HAUSER UTILITY CLEARANCES COX COMMUNICATION Completed
10/11/2006 TAMI HAUSER UTILITY CLEARANCES SOUTHWEST GAS CORP Completed
10/11/2006 TAMI HAUSER UTILITY CLEARANCES EL PASO NATURAL GAS Passed
10/11/2006 TAMI HAUSER UTILITY CLEARANCES KINDER MORGAN ENERGY Passed
10/16/2006 JOSE ORTIZ DOT TRAFFIC REVIEW Approved
10/27/2006 GARY WITTWER DOT LANDSCAPE REVIEW Approved
11/06/2006 LANCE PETERSON DOT STREET MAINTENANCE REVIEW Approved
11/08/2006 RICHARD LEIGH DOT ENGINEERING REVIEW Denied November 7, 2006

SUBJECT: Gracious Estates, PIA Plan T06PI0039

PROJECT REVIEWER: Richard Leigh, Senior Engineering Associate Permits and Codes Section

RESUBMITTAL REQUIRED: Permits and Codes Section has reviewed the PIA Plan and does not recommend approval of the PIA Plan at this time. The following comments need to be addressed in the next submittal.

1. Indicate book and page on cover sheet. Plat must be recorded before submittal of mylars for final review and approval.

2. Sheet 1: Provide DSMR number in note 43.

3. Sheet 3: Indicate inlet invert for the proposed 24" storm drain across Gracious Court.

4. Sheet 3: Provide a headwall for the outlet of the proposed 24" storm drain across Gracious Court.

5. Sheet 3: Provide a sidewalk scupper per PC/COT standards instead of a depressed curb opening at ± Station 15+75, 16 RT (Gracious Court).

6. Provide a profile of the proposed 24" storm drain across Gracious Court.

7. Clarify elevations called out for the headwall Indicate inlet invert for the proposed 24" storm drain across Gracious Court.

8. Indicate/provide slopes and slope treatments for the proposed cut and fill slopes in right-of-way.

9. Provide a headwall at the inlet and outlet of the proposed stormdrain in the cul-du-sac of Wildlife Drive.

10. Provide a sidewalk scupper per PC/COT standards instead of a depressed curb opening in the cul-du-sac of Wildlife Drive.

11. Sheet 6, Detail A & C: A minimum of 2' must be provided between the property line and the top of the slope any drainage channel.

12. Sheet 7, Detail L: Per PC/COT S.D. 108 a minimum of 1' 3" must be provided between the proposed storm drains.

If you have any questions, I can be reached at 791-3115 ext.448 or Richard.Leigh@tucsoz.gov
11/14/2006 TAMI HAUSER PIA COORDINATOR CUSTOMER CALLED; PLANS @ AMBASSADOR Completed
11/14/2006 TAMI HAUSER PIA COORDINATOR OUT TO CUSTOMER Completed