Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Plan Review Detail
Review Status: Completed
Review Details: PIA RESUBMITTAL
Plan Number - T06PI00039
Review Name: PIA RESUBMITTAL
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
10/11/2006 | TAMI HAUSER | ENGINEERING | REVIEW | Needs Review | |
10/11/2006 | TAMI HAUSER | UTILITY CLEARANCES | COT STREETS DIVISION | Completed | |
10/11/2006 | TAMI HAUSER | UTILITY CLEARANCES | COT WATER NEW DEVELOPMENT | Completed | |
10/11/2006 | TAMI HAUSER | UTILITY CLEARANCES | PC WASTEWATER MGMT | Completed | |
10/11/2006 | TAMI HAUSER | UTILITY CLEARANCES | QUEST COMMUNICATION | Completed | |
10/11/2006 | TAMI HAUSER | UTILITY CLEARANCES | TUCSON ELECTRIC POWER CO | Completed | |
10/11/2006 | TAMI HAUSER | UTILITY CLEARANCES | COX COMMUNICATION | Completed | |
10/11/2006 | TAMI HAUSER | UTILITY CLEARANCES | SOUTHWEST GAS CORP | Completed | |
10/11/2006 | TAMI HAUSER | UTILITY CLEARANCES | EL PASO NATURAL GAS | Passed | |
10/11/2006 | TAMI HAUSER | UTILITY CLEARANCES | KINDER MORGAN ENERGY | Passed | |
10/16/2006 | JOSE ORTIZ | DOT TRAFFIC | REVIEW | Approved | |
10/27/2006 | GARY WITTWER | DOT LANDSCAPE | REVIEW | Approved | |
11/06/2006 | LANCE PETERSON | DOT STREET MAINTENANCE | REVIEW | Approved | |
11/08/2006 | RICHARD LEIGH | DOT ENGINEERING | REVIEW | Denied | November 7, 2006 SUBJECT: Gracious Estates, PIA Plan T06PI0039 PROJECT REVIEWER: Richard Leigh, Senior Engineering Associate Permits and Codes Section RESUBMITTAL REQUIRED: Permits and Codes Section has reviewed the PIA Plan and does not recommend approval of the PIA Plan at this time. The following comments need to be addressed in the next submittal. 1. Indicate book and page on cover sheet. Plat must be recorded before submittal of mylars for final review and approval. 2. Sheet 1: Provide DSMR number in note 43. 3. Sheet 3: Indicate inlet invert for the proposed 24" storm drain across Gracious Court. 4. Sheet 3: Provide a headwall for the outlet of the proposed 24" storm drain across Gracious Court. 5. Sheet 3: Provide a sidewalk scupper per PC/COT standards instead of a depressed curb opening at ± Station 15+75, 16 RT (Gracious Court). 6. Provide a profile of the proposed 24" storm drain across Gracious Court. 7. Clarify elevations called out for the headwall Indicate inlet invert for the proposed 24" storm drain across Gracious Court. 8. Indicate/provide slopes and slope treatments for the proposed cut and fill slopes in right-of-way. 9. Provide a headwall at the inlet and outlet of the proposed stormdrain in the cul-du-sac of Wildlife Drive. 10. Provide a sidewalk scupper per PC/COT standards instead of a depressed curb opening in the cul-du-sac of Wildlife Drive. 11. Sheet 6, Detail A & C: A minimum of 2' must be provided between the property line and the top of the slope any drainage channel. 12. Sheet 7, Detail L: Per PC/COT S.D. 108 a minimum of 1' 3" must be provided between the proposed storm drains. If you have any questions, I can be reached at 791-3115 ext.448 or Richard.Leigh@tucsoz.gov |
11/14/2006 | TAMI HAUSER | PIA COORDINATOR | CUSTOMER CALLED; PLANS @ AMBASSADOR | Completed | |
11/14/2006 | TAMI HAUSER | PIA COORDINATOR | OUT TO CUSTOMER | Completed |