Plan Number: T06PI00038
Parcel: Unknown

Address:
2430 S SWAN RD

Review Status: Completed

Review Details: PIA RESUBMITTAL

Plan Number - T06PI00038
Review Name: PIA RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/12/2006 TAMI HAUSER ENGINEERING REVIEW Needs Review
09/14/2006 RICHARD LEIGH DOT ENGINEERING REVIEW Denied September 26, 2006

SUBJECT: Tucson Border Patrol, Golf Links Rd and Swan Rd, PIA Plan T06PI0034, I-2006-066

PROJECT REVIEWER: Richard Leigh

RESUBMITTAL REQUIRED: Permits and Codes Section has reviewed the PIA Plan and does not recommend approval of the PIA Plan at this time. The following comments need to be addressed in the next submittal.

1. The Basis of elevation must be referenced to a benchmark listed in a City of Tucson (COT) field book.

2. A flood plain use permit will be required for the placement of the storm drain across the Golf Links Road driveway. Per Chapter 26 of the COT code any development within a regulatory floodway, flows exceeding 100 cfs, requires a flood plain use permit. Contact the City of Tucson, Development Services Department for additional information. Reference Floodplain us number on cover sheet.

3. Provide stationing, offsets and elevations for all the proposed improvements (beginning and ending of proposed curbs, ECR, BCR, drainage structures, curb openings, Etc.).

4. Provide all details (inverts, pipe lengths and etc.) for the proposed slotted drain relocation on this plan set. Additionally, reference the slotted drain details (J/12) in the plan view.

5. Sheet 3 & 4: The centerline station labeling for Golf Links Road is incorrect. Stations on centerline do not match stations on plan view.

6. Sheet 3 & 4: Correct page references, see redlined plans.

7. Sheet 4: Stationing for Swan Road must be based off of stationing shown on cover sheet.

8. Provide cutoff wall details for the proposed headwalls for the storm drain across the Golf Links Road driveway.

9. Sheet 4: Reference the cross section (detail 3/9) for the storm drain across the Golf Links Road driveway in the plan view.

10. Per City of Tucson drafting standards and per typical industry engineering standards the roadway profile must be horizontally aligned with the plan view and stations labeled on profile for beginning and ending of proposed curbs, ECR, BCR, drainage structures, curb openings, Etc.


If you have any questions, I can be reached at 791-3115 ext.448 or Richard.Leigh@tucsoz.gov
09/25/2006 JOSE ORTIZ DOT TRAFFIC REVIEW Approv-Cond September 25, 2006
ACTIVITY NUMBER: T06PI00038
PROJECT NAME: U S Sector Border Patrol
PROJECT ADDRESS: 2430 S Swan Rd
PROJECT REVIEWER: Jose E. Ortiz PE, Traffic Engineer

Resubmittal Required: Traffic Engineering recommends a conditional approval of the PIA Plan; therefore address the following comments prior to submitting the mylars.

The following items must be revised or added to the plan.

1. Sheet 6 of 17: the existing 'THRU TRAFFIC MERGE LEFT' sign should be illustrated and called out to be relocated as shown in HDR's previous submitted plans.

2. Sheer 6 of 17: Under the SIGNING GENERAL NOTES, Note 1 needs to be modified; modify the wording "2000 Edition" to " 2003 Edition"


If you have any questions, I can be reached at 791-4259 x305 or Jose.Ortiz@tucsonaz.gov
09/26/2006 GARY WITTWER DOT LANDSCAPE REVIEW Approved
09/29/2006 LANCE PETERSON DOT STREET MAINTENANCE REVIEW Approved
10/03/2006 TAMI HAUSER PIA COORDINATOR CUSTOMER CALLED; PLANS @ AMBASSADOR Completed
10/03/2006 THAUSER1 CONSTRUCTION ESTIMATE REVIEW Needs Review
10/03/2006 TAMI HAUSER PIA COORDINATOR OUT TO CUSTOMER Completed