Plan Review Detail
Review Status: Completed
Review Details: PIA RESUBMITTAL
Plan Number - T06PI00029
Review Name: PIA RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/01/2006 | TAMI HAUSER | ENGINEERING | REVIEW | Denied | |
| 08/01/2006 | TAMI HAUSER | UTILITY CLEARANCES | COX COMMUNICATION | Passed | SUBMIT UTILITY CLEARANCE LETTERS FOR ALL UTILITIES EXCEPT COX COMMUNICATIONS AND KINDER MORGAN. |
| 08/01/2006 | TAMI HAUSER | UTILITY CLEARANCES | KINDER MORGAN ENERGY | Passed | SUBMIT UTILITY CLEARANCE LETTERS FOR ALL UTILITIES EXCEPT COX COMMUNICATIONS AND KINDER MORGAN. |
| 08/17/2006 | GARY WITTWER | DOT LANDSCAPE | REVIEW | Denied | See previous comments. Nothing submitted this time. |
| 08/22/2006 | TAMI HAUSER | UTILITY CLEARANCES | SOUTHWEST GAS CORP | Completed | SUBMIT UTILITY CLEARANCE LETTERS FOR ALL UTILITIES EXCEPT COX COMMUNICATIONS AND KINDER MORGAN. |
| 08/22/2006 | TAMI HAUSER | UTILITY CLEARANCES | EL PASO NATURAL GAS | Completed | SUBMIT UTILITY CLEARANCE LETTERS FOR ALL UTILITIES EXCEPT COX COMMUNICATIONS AND KINDER MORGAN. |
| 08/22/2006 | TAMI HAUSER | UTILITY CLEARANCES | COT STREETS DIVISION | Completed | SUBMIT UTILITY CLEARANCE LETTERS FOR ALL UTILITIES EXCEPT COX COMMUNICATIONS AND KINDER MORGAN. |
| 08/22/2006 | TAMI HAUSER | UTILITY CLEARANCES | COT WATER NEW DEVELOPMENT | Completed | SUBMIT UTILITY CLEARANCE LETTERS FOR ALL UTILITIES EXCEPT COX COMMUNICATIONS AND KINDER MORGAN. |
| 08/22/2006 | TAMI HAUSER | UTILITY CLEARANCES | PC WASTEWATER MGMT | Completed | SUBMIT UTILITY CLEARANCE LETTERS FOR ALL UTILITIES EXCEPT COX COMMUNICATIONS AND KINDER MORGAN. |
| 08/22/2006 | TAMI HAUSER | UTILITY CLEARANCES | QUEST COMMUNICATION | Completed | SUBMIT UTILITY CLEARANCE LETTERS FOR ALL UTILITIES EXCEPT COX COMMUNICATIONS AND KINDER MORGAN. |
| 08/22/2006 | TAMI HAUSER | UTILITY CLEARANCES | TUCSON ELECTRIC POWER CO | Completed | SUBMIT UTILITY CLEARANCE LETTERS FOR ALL UTILITIES EXCEPT COX COMMUNICATIONS AND KINDER MORGAN. |
| 08/28/2006 | LANCE PETERSON | DOT STREET MAINTENANCE | REVIEW | Denied | We have reviewed these plans and have the following comments: 1. How does the common area channel tie into the Jullian Wash? Landscaping: 1. Please submitt the proposed landscaping plan to Paul Rosenboom at 4004 S. Park Avenue, phone 791-3154. No further comments. 8/28/06 *********Additional Review******* Design consultant provided information on how channel will tie into the Jullian Wash. Landscape Comments still a concern. No further Comments. 9/14/06 |
| 08/28/2006 | Estevan Tineo | DOT ENGINEERING | REVIEW | Denied | (La Estancia De Tucson, Lots 411-664, T06PI00029, I-2006-030): The following comments, at a minimum, must be addressed in the next submittal. 1. Sheet 1 of 24: Add recordation information (Book and Page). 2. Sheet 2 of 24: Provide Floodplain Use Permit number on the plan. 3. Sheet 3 of 24: Detail C, add "No Parking" to the PDA note. 4. Sheet 3 of 24: Detail D, add "No Parking", and "4'- Sidewalk". 5. Sheet 4 of 24: Detail I, Call out 6' transition (instead of 3') for scupper. 6. Sheet 4 of 24: Detail I, Call out smooth steel painted bars not rebar. 7. Sheet 4 of 24: Detail I, Include railing in front of scupper when drop (Elev. A minus Elev. B) exceeds 1'. 8. Sheet 5 of 24: Detail C, provide 6' rectangular concrete section. Also gutter depression must not be in travel way, this includes the Bike lane (this is a safety issue). 9. Sheet 5 of 24: Detail B, Provide 6' transition. Also, is proposed grate behind gutter and will this grate perform as designed? 10. Per previous comment 19, provide structural details for proposed structures. Do not submit the plans revisions unless these details are included. 11. Sheet 20 of 24: include inlet and outlet cut-off walls. 12. Sidewalk ramp longitudinal slopes into proposed scuppers must not exceed 12:1, please check SC/7-Sheet 2/24, SC/2-Sheet 13/24, SC/4-Sheet 18/24, and SC/5-Sheet 21/24. |
| 08/28/2006 | JOSE ORTIZ | DOT TRAFFIC | REVIEW | Approved | |
| 09/01/2006 | THAUSER1 | CONSTRUCTION ESTIMATE | REVIEW | Needs Review | |
| 09/01/2006 | TAMI HAUSER | PIA COORDINATOR | CUSTOMER CALLED; PLANS @ AMBASSADOR | Completed | |
| 09/01/2006 | TAMI HAUSER | PIA COORDINATOR | OUT TO CUSTOMER | Completed |