Permit Review Detail
Review Status: Completed
Review Details: FLOODPLAIN
Permit Number - T06OT03044
Review Name: FLOODPLAIN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/22/2006 | SUZANNE BOHNET | ENGINEERING | REVIEW | Approved | Structure built in 1998. No copy of El Cert found by applicant or permit for structure requirements (i.e., FFE). Per FIRM panel, flood zone Shaded X is shallow 100-year. Therefore, minimum FFE is 2' above highest adjacent natural grade. Per approved Development Plan in 1998, FFE is 2.9' above natural grade. Interior Tenant Improvements approved as structure is conforming with Ordinance. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/07/2006 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |