Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T06OT03022
Parcel: 140411190

Address:
3230 E ELVIRA RD

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T06OT03022
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/16/2007 JASON GREEN ENGINEERING REVIEW Denied Will review with Site Plan activity
02/16/2007 JASON GREEN ENGINEERING REVIEW Denied March 22, 2007
FLOODPLAIN USE PERMIT NO.: T06OT03022
ADDRESS: 3230 E Elvira Rd Lot 118, Tucson Arizona 85706
PROPERTY OWNER: Bourn Partners, 520-977-6369

The applicant is authorized to use a portion of the City of Tucson flood-prone and/or erosion hazard area as shown on the subdivision plat covering this parcel as recorded in Book 37, Page 083, at the office of the Pima County Recorder, specifically described as:

A portion of Airport Commerce Center Lot 118 (Formerly 139-37-1190)

For the purpose of constructing a Commercial Building.

The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard Area Regulations, and are bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations require application for, review and approval of an additional Floodplain Use Permit.


This floodplain use permit is issued with the following 10 conditions:

1) This project is located in a City of Tucson Floodplain as shown in Book 37, Page 083.

2) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties.

3) For purposes of this permit the following flood elevations shall be used:
Base Flood Elevation (BFE) = 2611.9 feet NAVD 1988
Regulatory Flood Elevation (RFE) = 2613.75 feet NAVD 1988
Building is to have lowest finished floor elevated at or above the Regulatory Flood Elevation (RFE) and lowest point of any attached appliances is to be at or above the Regulatory Flood Elevation (RFE).

4) Floodplain Approval of elevation certificate, prepared by an Arizona State Registered Land Surveyor, is required prior to the 1010/1015 inspection (P2S) and prior to finished construction or Final Inspection (P2F). The Elevation Certificate must include the identity and elevation of the lowest service equipment/machinery servicing the commercial building as well as the identity and location of all other equipment/machinery servicing the building.

5) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T06OT03022 FOR INFORMATION PLEASE CALL 791-5550."

6) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval.

7) Contractor will need to call for floodplain use permit inspections by Development Services Department Engineering Division Inspection Team (791-5550) prior to and after the installation of the replacement manufactured home.

8) All work shall conform to the approved site plan, which is made part of this permit, T06CM05979.

9) This Floodplain Use Permit is issued prior to the approval of the improvement plans/permit. Copies of these documents will need to be kept in a readily accessible location on site at all times.

10) This permit is specific to the improvements for 3230 E Elvira Lot 118 as indicated on the approved plans. It shall not apply to any other structure or property, whether attached or unattached, not specified under this permit.

This Floodplain Use Permit will be automatically revoked and becomes invalid for non-compliance to conditions set forth in this permit. Also, this permit will expire one year from its date of issue. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Division.

APPLICANT NAME: MPE
ADDRESS: 3619 E Speedway Blvd, Suite 101, AZ 85716
PHONE: 520-990-6866
CONTRACTOR: Bourn Partners
ADDRESS: 3915 E Broadway Blvd, Suite 400, Tucson AZ 85714
PHONE: 520-977-6369

(EXPIRATION DATE) Month: 04 Day: 01 Year: 2007



SIGNATURE OF APPLICANT DATE
The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions.

Final Status

Task End Date Reviewer's Name Type of Review Description
05/11/2007 SHANAE POWELL OUT TO CUSTOMER Completed
05/11/2007 SUE REEVES REJECT SHELF Completed