Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T06OT02725
Parcel: 13631011Q

Review Status: Completed

Review Details: FLOODPLAIN

Permit Number - T06OT02725
Review Name: FLOODPLAIN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/31/2006 SUZANNE BOHNET ENGINEERING REVIEW Approved October 31, 2006

FLOODPLAIN USE PERMIT NO.: T06OT02725
RELATED PERMIT NO.: T06MH00057
ADDRESS: 9801 E. Millmar Rd.
APPLICANT: Taylor Carter

The applicant is authorized to use a portion of the City of Tucson property described as (legal description): ELY PTN E663.25' E686.32' W981.32' OF LOT 7 10.03 AC SEC 35-14-15

1. This permit is for the purpose of a Manufactured Home installation within a mapped Special Flood Hazard Area (SFHA), Zone AE, as shown on the Flood Insurance Rate Map (FIRM), Community Panel No. 040076-04019C-2270K, effective date February 8, 1999.

2. The proposed structure is impacted by the regulatory floodplain. For purposes of this permit, the following elevation requirements apply:

Base Flood Elevation (BFE) = 2744.0 feet per the National Geodetic Vertical Datum (NGVD '29)
Regulatory Flood Elevation (RFE) = 2745.0 feet per the National Geodetic Vertical Datum (NGVD '29)

The bottom of the lowest structural member and all attached equipment of the manufactured home must be elevated to the Regulatory Flood Elevation (RFE). All service utilities, machinery, equipment (i.e. furnaces, water heaters, heat pumps, air conditioners and their associated equipment, including all electrical equipment), must be elevated to the Regulatory Flood Elevation (RFE). An Elevation Certificate completed and certified by an Arizona Registered Land Surveyor or Arizona Registered Professional Civil Engineer must be returned to Development Services Department, Engineering Division, on the first floor of the County/City Public Works Building at 201 N. Stone Avenue prior to any final inspection.

3. Any additional improvements, including block walls, fences or pools, will require a separate Floodplain Use Permit prior to construction.

Final Status

Task End Date Reviewer's Name Type of Review Description
11/02/2006 GERARDO BONILLA OUT TO CUSTOMER Completed