Permit Number: T06OT01109
Parcel: 116160580

Address:
714 N ANITA AV

Review Status: Completed

Review Details: FLOODPLAIN

Permit Number - T06OT01109
Review Name: FLOODPLAIN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/25/2006 JASON GREEN ENGINEERING REVIEW Approved DATE: April 26, 2006
SUBJECT: Demolition; shed, bearing wall, and old metal roofing- Engineering Review
ADDRESS: 714 N Anita Ave, Tucson Arizona 85705
PROPERTY OWNER: Gary L Shaw
LOCATION: T14S R13E Section 11 A portion of Parcel 116-16-0580, MCKINLEY PARK AMENDED W2 LOT 39 BLK 1
REVIEWER: Jason Green and Elizabeth Eberbach, PE
ACTIVITY NUMBER: T06CM1141

SUMMARY: The Demo plan and building review documents, described as 714 N Anita Ave, were received and reviewed by Engineering Division. The Floodplain Use Permit application, T06OT01109, will be issued and is to include valuation of the improvement and location map, for the purpose of an addition to an existing, non-conforming floodprone structure. Engineering Division recommends approval of the Floodplain Use Permit.

CONDITIONS OF PERMIT:

1) The associated improvements are with permit activity number T06OT01109 (Floodplain Use Permit) and T06CM01141 (Demo plans).
2) Any improvements to the structural building for this project are considered a substantial improvement to an existing floodprone structure if the value of this new improvement is 50% or more than the value of the existing structure in present day value. If the project is determined to be a substantial improvement, and, if it is determined that the lowest floor elevation is below the regulatory floor elevation, a design submittal, and review and acceptance of the submittal for floodproofing will be required and shall conform to City of Tucson and FEMA floodplain development requirements.
3) All future improvements to the building structures shall be submitted with a Floodplain Use Permit application. It shall be the responsibility of the property owner, or its authorized agent, to supply the following with future Floodplain Use Permit Applications:
a) Value of improvement in U. S. Dollars.
b) Type of assessment used for valuation.
c) Cumulative value of the building structure.
d) A calculated percent improvement.
e) Title of the improvement.
f) Description of improvement.
g) Provide 8-1/2" x 11" map locating improvement.
h) Provide permit activity number(s).
4) The applicant attests to the fact that the plans and documents submitted represent all of the improvements that will be done to the existing building, and that all additions, improvements or repairs to the building are included in the construction plans and/or documents herewith. No other improvements, repairs, reconstruction, additions or remodeling have been made to the structure that is not indicated in the attached plans and/or documents.
5) This permit is specific to the improvements for 714 N Anita Ave specified as the construction of an addition to a nonconforming structure as shown on this plan. It shall not apply to any other structure or property, whether attached or unattached, not specified under this permit.
6) Copies of the improvement plans/permit documents shall be kept in a readily accessible location on site at all times.


If you have any questions, I can be reached at 791-5550, extension 1189.



Jason Green, CFM
Senior Engineer Associate
Engineering Division
Development Services