Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T06OT00819
Parcel: 110073060

Address:
2617 N WALNUT AV

Review Status: Completed

Review Details: FLOODPLAIN

Permit Number - T06OT00819
Review Name: FLOODPLAIN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/12/2006 SUZANNE BOHNET ENGINEERING REVIEW Approved April 13, 2006

FLOODPLAIN USE PERMIT NO.: T06OT00819
ADDRESS: 2617 N. Walnut Ave.
APPLICANT: G and S Homes

The applicant is authorized to use a portion of the City of Tucson property described as (legal description): Bonita Vista Lot 19

1. This permit is for the purpose of construction of a single-family residence within a mapped Flood Hazard Area, Zone X (Shaded), as shown on the Flood Insurance Rate Map (FIRM), Community Panel No. 040076-04019C-1644K, effective date February 8, 1999.

2. The proposed structure is impacted by the regulatory floodplain. For purposes of this permit, the following elevation requirements apply:

Base Flood Elevation (BFE) = 0.5 feet above highest adjacent natural grade
Regulatory Flood Elevation (RFE) = 1.5 feet above highest adjacent natural grade

Residence to have lowest finished floor elevated at or above the Regulatory Flood Elevation (RFE). Service facilities, such as electrical, heating and cooling equipment, shall be constructed at or above the same minimum elevation as the FFE and either be placed on flood proof materials or be adequately flood proofed.

A Building Under Construction Elevation Certificate, completed and certified by an Arizona Registered Land Surveyor, must be returned to the Engineering Division of the Development Services Department. A hold will be placed on the slab inspection (P2S) until the Elevation Certificate has been returned and approved.

A Finished Construction Elevation Certificate must be returned to the Engineering Division and approved prior to the issuance of the certificate of occupancy.

3. Any additional improvements, including block walls, fences or pools, will require a separate Floodplain Use Permit prior to construction.

Final Status

Task End Date Reviewer's Name Type of Review Description
04/17/2006 SUE REEVES APPROVAL SHELF Completed
04/17/2006 CINDY AGUILAR OUT TO CUSTOMER Completed