Permit Number: T06OT00267
Parcel: 136142080

Address:
8200 E STELLA RD

Review Status: Completed

Review Details: FLOODPLAIN

Permit Number - T06OT00267
Review Name: FLOODPLAIN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/08/2006 PAUL MACHADO ENGINEERING REVIEW Approv-Cond February 09, 2006

FLOODPLAIN USE PERMIT NO. T06OT00267
ADDRESS: 8200 E Stella Road
PROPERTY OWNER'S NAME: Bednar Design and Construction, Inc.

The applicant is authorized to use a portion of the flood hazard area in the City of Tucson on the property described as (legal description):

Being a portion of the South Half of Section 28, Township 14 South, Range 15 East, Gila and Salt River Meridian, Pima County, Arizona.

The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and are particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit.

The following conditions shall apply to this permit. (Refer to Chapter 26 "FLOODPLAIN, STORMWATER, AND EROSION HAZARD MANAGEMENT" for additional information ):

1. All work including but not limited to the placement of fill to channelize the Atterbury Wash shall conform to the attached plans (Drainage Report and Grading plans) which are made part of this permit. The fill shall be compacted to a minimum of 95% density to the elevations shown on the approved Grading Plan.

2. This Permit is issued only for channelizing the Atterbury Wash and the installation of the proposed fill in the FEMA Floodplain on the east side of the Atterbury Wash, which would result in removing the floodplain area from the Atterbury Wash FEMA designated 100-year Floodplain. The actual removal of the impacted area from the FEMA Floodplain Maps happens after the following steps are taken:

a. Completion of the permitted channelization and the fill work after the Grading Permit is issued.
b. Certifying the fill finished grade elevations by a registered land surveyor. The grades must match the information shown the approved Grading Plan and the information submitted with the approved CLOMR application.
c. The certified grades and all supporting data shall be submitted to FEMA for their review and approval.

Once FEMA approves the submittal and issues the LOMR, the Developer can start the construction of homes in the impacted area.

This Permit also includes the installation of Lakeside View Drive within the regulatory floodplain area.

Please be advised that lots 50 through 59 are not part of this permit since they are not impacted by the FEMA designated 100-year floodplain. The Developer can construct homes on these lots once the Grading Plan is approved.

3. The existing drainage patterns at the property lines shall not be obstructed other than what is shown on the attached plans.

4. Within 5 (five) days of issuance of this permit, through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "Construction proceeding under requirements of City of Tucson Floodplain Use Permit No. T06OT00267. For information please call 791-5550."

5. Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties.

6. This permit becomes invalid and is subject to additional floodplain review, if any required development permit (s') changes the configuration of the structure and or site development.


This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions set forth in this permit are not complied with. Also, this permit will expire one year from its date of issue. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Section.


(EXPIRATION DATE) Month: 02 Day: 09 Year: 2007
Note the final inspection or certificate of occupancy will be on hold, for lots 36 through 49 until the LOMR is issued by FEMA


APPLICANT NAME: T J Bednar
ADDRESS: 7604 N La Cholla Blvd.
PHONE NO.: (520) 293-7203


________________________ __________
APPLICANT'S SIGNATURE DATE

The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions.

Final Status

Task End Date Reviewer's Name Type of Review Description
03/02/2006 SUE REEVES APPROVAL SHELF Completed
03/02/2006 GBONILL1 OUT TO CUSTOMER Completed