Permit Number: T06OT00241
Parcel: 13409019L

Review Status: Completed

Review Details: SITE

Permit Number - T06OT00241
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/30/2006 JIM EGAN FIRE REVIEW Approved
02/08/2006 ANDREW CONNOR NPPO REVIEW Denied 1. Submit landscape plan to verify site meets code requirements at time of approval.
02/08/2006 ANDREW CONNOR LANDSCAPE REVIEW Denied 1. Submit landscape plan to verify site meets code requirements at time of approval.

2. The planting plan and layout calculations will include both proper and common name of all existing vegetation to remain in place.

3. Additional comments may apply.
03/02/2006 TERRY STEVENS ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Terry Stevens FOR: David Rivera
Lead Planner Principal Planner

PROJECT:T06OT00241
140 S. Camino Seco
Parking Lot Restripe
Site Plan

Transmittal date:1st Review 3/7/06

COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. The provided last approved site plan is not complete. Please provide the last stamped and approved site plan for the area to the north and west. This review is based on the submitted as built plan and the last approved site plan for the area to the south. If the area to the north and west is not the same as on the last approved site plan further comments may be forth coming.

2. As per the submitted last approved site plan this site was approved for use as an Industrial Business and Retail/Office use. The new plans submitted indicate a change of use to a Retail Shopping Center. Per discussion with zoning staff (Craig Gross, David Rivera, Patricia Gehlen) because of the change of use the following comments will apply to this site.

3. Loading zones must be provided as per LUC Sec. 3.4.5.3. Based on the size and location of the buildings for the southern portion of this site, 4 loading zones are required. Provide the square footage of all buildings in order to calculate the number of required loading zones for the rest of this site. See LUC Sec. 3.4.4.1.B.2 for locational requirements for loading zones. Currently the are no loading zones indicated on the submitted site plans.

4. Pedestrian circulation paths as per DS 2-08.3.1, DS 2-08.4.1, and DS 2-08.5.1 are required. The indicated 6' walkways will require to be changed to physically separated 4' wide concrete sidewalks which then can be depressed at and overhead door locations.

The pedestrian circulation path must provide access and a handicap accessible route from the street to the entire site. Pedestrian refuge areas (5' in width) and sidewalks (4' in width) are required between any building and an adjacent PAAL. Clearly indicate the location of all handicap ramps and crosswalks.

Access ramps at crosswalks and handicap parking access aisles connecting to sidewalks must be provided. In addition Truncated Dome (early warning systems) must be added to all access ramps where transitioning from the pedestrian area to the vehicular use area or at HC access aisles transitioning to the sidewalk area

5. Bicycle parking spaces are required as per LUC Sec. 3.3.5.6.A.2 and DS 2-09. Clearly indicate the type, location, directional signage, and the number of required and proposed bicycle parking spaces

6. It is acknowledged that the vehicle parking spaces required is for a General Merchandise Sales: Shopping Center for a shopping center with a gross floor area greater than 50,000 square feet per LUC Sec. 3.3.5.6.A.1. Per LUC Sec. 6.2.19 in order to be considered a shopping center 50% or more of the use must be retail. The required parking spaces as per this code is 1 space per 200 square feet of gross floor area. The gross floor area provide in the calculations indicate 78,200 square feet. Based on the 78,200 sq. ft. the required number of parking spaces for this site is 391 parking spaces. The parking calculations provided indicate that 204 parking spaces are proposed. 187 more parking spaces are required per the provided calculations. The provided restriped plan indicates that there are 183 parking spaces provided. Based on the provided restripe plan an additional 208 parking spaces are required. Please clarify.

Two parking spaces have been added at the south side of the building nearest the south property line. They appear to have been located in a previous landscaped area. If this is a required landscape area the parking spaces will have to be relocated. See landscape reviewers comments. In the same area a dumpster is indicated which was not on the last approved site plan. Clearly indicate the required 24' width for the PAAL in this area.

Wheel stops or barriers will be required at any parking spaces which are required to prevent vehicles from overhanging into required landscape areas, reducing of sidewalk widths to less than 4', or to prevent damage to fences or walls. See DS 3-05.2.3.C.

Handicap parking spaces must be provided as per IBC Sec. 1106.1. The required number of spaces is based on the number of provided parking spaces at a ratio of 1 space for every 25 parking spaces provided. Van accessible handicap parking spaces are also required as per IBC Sec. 1106.5 at a ratio of 1 space for every 6 handicap parking spaces required. Please provide.


7. Indicate the existing property lines. It appears the dumpsters indicated along the southern property line of this site may be located on the adjacent property.

8. Depending on changes to the plan and responses to the above comments further comments may be forth coming.

If you have any questions about this transmittal, please call Terry Stevens, (520) 791-5550 ext. 2000.
03/08/2006 TERRY STEVENS ZONING HC SITE REVIEW Denied see zoning comments
03/10/2006 PAUL MACHADO ENGINEERING REVIEW Denied To: Intertech DATE: March 9, 2006
Architects
6089 E. Grant Road
Tucson, Arizona 85712

SUBJECT: Camino Seco Business Park, 140 S. Camion Seco
Site plan T06OT00241 (First Review)
T14S, R15E, Section 16

RESUBMITTAL REQUIRED: Site Plan and Drainage Report.

The Site Plan (SP) and Drainage Report (DR) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Site Plan:

1. Please include a response letter to the comments along with the corrected copies of the SP.
2. This review was performed assuming a change of use, hence full-code compliance is required.
3. This site may be impacted by City of Tucson floodplain. See Drainage Report comment no. 2.
4. 5-year threshold retention is required.
5. Please provide property description per D.S. 2-02.2.1.3.
6. Please label lot dimensions and bearings per D.S. 2-02.2.1.5.
7. Label existing and future sight visibility triangles per D.S. 2-02.2.1.10.
8. Fully dimensioned loading space(s) and maneuvering area(s) per D.S. 2-02.2.1.14.
9. Please provide Drainage patterns and finished grades per D.S. 2-02.2.1.16.
10. Please show dimensioned right-of-way, including any applicable Major Streets and Routes (MS&R) Plan right-of-way per D.S. 2-02.2.1.19.
11. Add the basin(s) maintenance responsibility note per S.M.D.D.F.M. 2.3.1.6 C 1 and 2 to the SP.
12. Dimension from street monument lines to existing and proposed curbs, sidewalks, driveways, and utility lines per D.S. 2-02.2.1.21.
13. Show Site plan number (T06OT00241) on all sheets per D.S. 2-02.2.1.29.
14. Show refuse container location, size, and access thereto fully dimensioned per D.S. 2-02.2.1.32 and D.S. 6-01.0.
15. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information.
16. List the consulting engineer and the owner/developer on the plans with the pertinent information.

Drainage Report:
1. Please include a response letter to the comments along with the corrected copies of the DR.
2. This site may be impacted by City of Tucson floodplain. An analysis of offsite drainage impacting the site will be required.
3. A Drainage report is required for any site greater than one acre in size or for any site subject to detention requirements…..per S.M.D.D.F.M., chap. II, 2.1.2.
4. The content and format of the Drainage Report should follow S.M.D.D.F.M., chap. II, 2.2.
5. Show the project address or administration address on the cover sheet of the DR.
6. If applicable, add the basin(s) maintenance responsibility note and checklist per S.M.D.D.F.M. 2.3.1.6 C 1 and 2 to the DR.

If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@tucsonaz.gov
Paul P. Machado
Senior Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 791-5550 x1193 office
(520) 879-8010 fax
C:/140 S. Camino Seco Site

Final Status

Task End Date Reviewer's Name Type of Review Description
03/20/2006 AKLAPPE1 OUT TO CUSTOMER Completed
03/20/2006 SUE REEVES REJECT SHELF Completed